Kontrol Bağlantı uçları
GMD SERİSİ HIZ KONTROL CİHAZLARI
KOLAY BAŞLANGIÇ KLAVUZU
NOT : Bu kılavuz kolay devreye almak için basitleştirilerek hazırlanmıştır. m
detaylar için ana kullanma kılavuzunu okuyunuz!
HATA KODLARI
Kod
Açıklama
Oc1
Oc2
Oc3
Anlık Aşırı Akım
Ou1
Ou2
Ou3
Yüksek Gerilim
lu Alçak Gerilim
lin Giriş Faz Kaybı
Op1 Çıkış Faz Kaybı
Oh1 Yüksek Sıcaklık
Oh4 Motor Koruma
dbh Frenleme Drenci Sıcaklık Yüksek
Ol1
Ol2
Motor Aşırı Yük
Olu Inverter Aşırı Yük
er1 Hafıza Hatası
er2 Tuş Takı Haberleşme Hatası
er3 CPU Hata
er6 Operasyon Koruma
er7 Tune Hatası
er8 RS-485 Haberleşme Hatası
cof PID Geribesleme Kablo Hatası

Questions and Answers

  • S
    Shawn DickersonAug 3, 2025
    What to do if the motor doesn't start and an under bar appears on the GMTCNT GMD Inverter?
    • Z
      zwilliamsAug 3, 2025
      If the motor doesn't start when you press the key or enter a run forward (FWD) or reverse (REV) command, and an under bar appears on the LED monitor, it could be due to low DC link bus voltage. To check this, go to Menu #5 "Maintenance Information" in Programming mode on the keypad and select 5_01. The DC link bus voltage should be 200 VDC or below for three-phase 200 V class series and 400 VDC or below for three-phase 400 V class series. To resolve this, connect the GMTCNT Inverter to a power supply that meets its input specifications.
  • A
    Alexis MartinezNov 17, 2025
    How to fix a center bar appearing on the GMTCNT GMD LED monitor?
    • J
      joshua60Nov 18, 2025
      If a center bar (– –|– – –) appears on the LED monitor of your GMTCNT Inverter, here are a few things to check: * **Monitor Items:** If you're trying to view other monitor items, see if E43 = 10 (PID command) or 12 (PID feedback amount). If it is, set E43 to a value other than "10" or "12." * **PID Control:** To view a PID command or its feedback amount, ensure that PID control is enabled. Check if the PID control is disabled (J01 = 0). Set J01 to "1" (Enable process control, normal operation) or "2" (Enable process control, inverse operation). * **Timer:** To view other monitor items, check if E32 = 13 (Timer). Set E43 to a value other than "13." To view timer (s): Check if C21 = 0 (Disable). Set C21 to "1." * **Keypad/Cable Issues:** Ensure that pressing the key changes the disp...

Summary

Error Codes

Parameter Settings

Motor Operation Parameters

Parameters for configuring motor operation settings and characteristics.

Communication Parameters

Parameters for setting up communication protocols and data transfer.

Safety Precautions

Application and Installation Safety

Safety guidelines for applying the inverter and installing it safely.

Other Safety Warnings

Precautions regarding disposal, modifications, and general safety.

Preface and Usage Information

Harmonics Suppression Guidelines

Guideline concerning harmonic suppression for inverters.

Before Using the Inverter

Acceptance Inspection

Steps to check the inverter upon receiving it from the manufacturer.

External Views and Terminal Cover

Identification of external parts and access to terminal covers.

Mounting and Wiring

Operating Environment and Installation

Requirements for the installation environment and physical mounting.

Wiring Procedures and Precautions

Detailed steps for wiring main and control circuits, including safety.

Keypad Operation

Keypad Components and Functions

Description of keypad buttons, monitor, and potentiometer functions.

Operation Modes

Explanation of the different operation modes: Running, Programming, and Alarm.

Motor Operation

Test Run

Procedure for safely testing the motor and inverter connection.

Normal Operation

Steps for setting up and starting production runs after a successful test.

Function Codes

Function Code Tables

Overview and categorization of function codes for inverter setup.

Fundamental Functions (F Codes)

Details on basic settings and parameters for inverter operation.

Extension Terminal Functions (E Codes)

Configuration options for external control terminals and signals.

Control Functions (C Codes)

Settings related to control modes, frequency commands, and PID.

Motor Parameters (P and A Codes)

Parameters for configuring Motor 1 and Motor 2 characteristics.

Application and Link Functions (J and y Codes)

Specific application functions and communication setup options.

Troubleshooting

Alarm Codes

Reference table for alarm codes and their causes.

Abnormal Display Conditions

Troubleshooting guide for issues without specific alarm codes.

Maintenance and Inspection

Daily and Periodic Inspections

Procedures for routine checks to ensure reliable operation.

Replacement Parts and Inquiries

Information on periodically replaced parts and how to contact support.

Specifications

Standard Model Series

Technical specifications for 200V, 400V, and single-phase inverter models.

Terminal and Connection Details

Details on terminal functions and external signal connection diagrams.

Protective Functions

Description of the inverter's built-in protection features and alarms.

GMTCNT GMD Series Specifications

General IconGeneral
BrandGMTCNT
ModelGMD Series
CategoryInverter
LanguageEnglish