EasyManua.ls Logo

GMV NGV A3 - 5.2 COMPLETE MENÙ

Default Icon
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENG
NGV A3 VALVE
INSTALLATION, USE AND MAINTENANCE
36/ 53
10991483 EN -1.10 - 26.05.2023
5.2 COMPLETE MENÙ
1
NGV-A3 VX.XRXXHX
DIAGNOSTICS
5
NGV-A3 VX.XRXXHX
SETTINGS
8
NGV-A3 VX.XRXXHX
OUTPUT FUNC
1.1
Pressure // xx.x bar
5.1
Lift Ratio // x:x
8.1
Output 11-12 // FUN xx Nx
1.2
Temperature // xx.x C°
5.2
Jack Diam // xxx mm
8.2
Output 21-22 // FUN xx Nx
1.3
Ref.Speed // x.xx m/s
5.3
Pump Flow // xxx l/min
8.3
Output 31-32 // FUN xx Nx
1.4
In: S0123DICA
// 000000000
5.4
Map // xx
8.4
Output 41-42 // FUN xx Nx
1.5
Out: 1234YND
// 0000000
5.5
Pstat. min // xx.x bar
1.6
Supply // xx.x Vdc
5.6
Pstat.max // xx.x bar
1.7
Fly Time //
5.7
P min // xx.x bar
1.7.1
Total //xxx.x s
5.8
P full load // xx.x bar
1.7.2
Start -> Dec. // XXX.X s
5.9
P overload // xx.x bar
1.7.3
Dec. -> Stop //XXX.X s
5.10
P max // xx.x bar
5.11
Cool Temp // xx °C
5.12
Mode: Normal-Installation
2
NGV-A3 VX.XRXXHX
ALLARMS
6
NGV-A3 VX.XRXXHX
UP PARAMETERS
9
NGV-A3 VX.XRXXHX
TEST…
2.1
Alarm 01 // 00: No Alarm
6.1
Nom.Speed V0 // x.xx m/s
9.1
OverP. Value // Ent = Start
...
...
6.2
Int. Speed V1 // x.xx m/s
9.2
Pipe Rupture // Ent = Start
2.8
Alarm 08 // 00: No Alarm
6.3
Ins.Speed V2 // x.xx m/s
9.3
UCM UP test // Ent = Start
6.4
Slow Speed // x.xxx m/s
9.4
UCM Test up // Ent = Start
6.5
Relev. Speed // x.xxx m/s
9.5
VB test down // Ent = Start
3
NGV-A3 VX.XRXXHX
AL/FLT RESET
6.6
Acc. Profile // XS,S,ST,F,C
9.6
VB test up // Ent = Start
3.1
Reset ? ESC=NO ENT=YES
6.7
Dec.Profile // XS,S,ST,F,C
9.7
Run-Rdy test // No test
6.8
Start Delay // x.x s
9.8
S3 tuning // Ent =Start
4
NGV-A3 VX.XRXXHX
ADJUSTMENTS
7
NGV-A3 VX.XRXXHX
DN PARAMETERS
10
NGV-A3 VX.XRXXHX
ADVANCED
4.1
Start UP min // ±xx
7.1
Nom. Speed V0 // x.xx m/s
10.1
Password // -00000
4.2
Slow UP min // ±xx
7.2
Int.Speed V1 //x.xx m/s
10.2
Register..// R000 = +00000
4.3
High DN min // ±xx
7.3
Ins.Speed V2 // x.xx m/s
4.4
Slow DN min // ±xx
7.4
Slow Speed // x.xxx m/s
4.5
Start UP max // ±xx
7.5
Relev. Speed // x.xxx m/s
11
PARAMS…
4.6
Slow UP max // ±xx
7.6
Acc. Profile // XS,S,ST,F,C
11.1
Save User
4.7
High DN max // ±xx
7.7
Dec.Profile // XS,S,ST,F,C
11.2
Load User
4.8
Slow DN max // ±xx
11.3
Load Factory
4.9
Offset V0 UP // xxx mm
4.10
Offset V0 DN // xxx mm
4.11
Offset V1 UP // xxx mm
12
SOFTWARE UPG…
4.12
Offset V1 DN // xxx mm
12.1
Select file
12.2
ENT >> Start

Related product manuals