NGV A3 VALVE
INSTALLATION, USE AND MAINTENANCE
42/ 53
10991483 EN -1.10 - 26.05.2023
5.4 CHART OF OUTPUT PROGRAMMABLE FUNCTIONS
The outputs 11-12; 21-22; 31-32; 41-42 are programmable with a specific function.
Each function could be defined active as NO (Normally Open) or as NC (Normally Close)
Function
Description
PT01 Code
0
No function, output OFF
FUN00
1
Minimum pressure (see parameter 5.7 into the Programming section)
FUN01NC
FUN01NO
2
Maximum pressure
(see parameter 5.10 into the Programming section)
FUN02NC
FUN02NO
3
Maximum pressure or minimum pressure
FUN03NC
FUN03NO
4
Minimum temperature (<5°C)
FUN04NC
FUN04NO
5
Maximum temperature
(see parameter 5.11 into the Programming section)
FUN05NC
FUN05NO
6
Maximum temperature or minimum temperature
FUN06NC
FUN06NO
7
Full load (see parameter 5.8 into the Programming section)
FUN07NC
FUN07NO
8
Overload (see parameter 5.9 into the Programming section)
FUN08NC
FUN08NO
9
Signal UP
FUN09NC
FUN09NO
5.5 CHART OF FAILURES
Failure
Description
00: NO ALARM
No alarm
01: SUPPLY LOW
Low power supply < Vdc - 15%
02: SUPPLY HIGH
High power supply > 40 Vdc
03: PRESS. FAULT
Pressure transducer PT short circuit
04: TEMP. FAULT
Temperature transducer TT short circuit
05: STEP MOTOR
Stepping motor driver SM overheated
06: S1 VRP OPEN
Contact S1 (VRP) open with lift stopped
07: S1 VRP OPEN
Contact S1 (VRP) open at the end of a downward travel
08: VS-VD INPUT
Signals VS and D contemporaneous
09: PRESS. MAX
Maximum pressure > 5.10 PSTAT MAX
10: PRESS. MIN
Minimum pressure < 5.7 PSTAT MIN
11: OIL TEMP LOW
Minimum oil temperature < 5°C
12: OIL TEMP HI
Maximum oil temperature > 5.11 COOL TEMP
13: S3 CLOSED
Contact S3 (VBO) closed with lift stopped
14: S2 OPENED
Contact S2 (VBC) opened with lift stopped
15: S1 NOT OPEND
Contact S1 (VRP) did not opened during starting downward travel
16: S1 NOT CLOSD
Contact S1 (VRP) did not closed during end of downward travel
17: S2 NOT CLOSD
Contact S2 (VBC) did not closed during end of downward travel
18: S3 NOT CLOSD
Contact S3 (VBO) did not closed when VB opens
19: S2 NOT OPEND
Contact S2 (VBC) did not opened when VB opens
20: S1 ALRDY OPN
Contact S1 (VRP) open before starting upward travel
21: S1 NOT OPEND
Contact S1 (VRP) did not opened during starting or in high speed
22: S1 NOT CLOSD
Contact S1 (VRP) did not closed during end of upward travel
23: PARAM ERROR
Wrong parameters map for this sw release. Shown when [191] “xxx” . “xxx” =
numeric parameter value (list of possible values: 16 / 32 / 64 / 128 / 256 / 512).
24: CAN BUS ERROR
NGV-A3-03 el.card in use without an active serial connection to the control panel.
5.6 ACCESSORIES
Box MR
Box MRL
NGVA3-XX
Morsettiera
PT01
40370007 +
60200369
01: 70200334
2,5 mm: 60200397
70205360
61000010 +
02: 70200335
6,0 mm: 60200400
24VDC:80395002C
40990003
03: 70200336
10 mm: 60200401
12VDC:80395002C