Instruction Manual: Le Jurassien Ref 3701
General Characteristics:
Overall dimensions: H 710mm x W 772mm x D 462mm
Firebox: H 270mm x W 400mm x D 200mm
Rear flue outlet diameter: 125mm
Distance between floor and top of rear flue outlet: 530mm
Technical Data:
Maximum heating output: 9.5kW
Rated heated volume: 380m3
Normal speed consumption: anthracite: 1.3kg/h wood: 4kg/h
Low speed consumption: anthracite: 0.3kg/h wood: 0.6kg/h
Burn duration at low speed: more than 10 hours
Thermostatic air intake regulation using control knob on the right side panel of the heater.
Chimney & Connection:
Before the installation is carried out, ensure that the chimney is in good condition and will provide adequate draw, i.e.
1.5mm WG (0.06’’WG)
The chimney should be well insulated