EasyManua.ls Logo

GOK BHK 052 - User Manual

GOK BHK 052
160 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Originalanleitung / Artikel-Nr. 05 288 50 j Ausgabe 01.2017 / Ersatz für Ausgabe 02.2015
Montage- und Bedienungsanleitung
Behälterregler-Kombination PS 25 bar
Durchgangsform zum Direktanschluss an Gasbehälter
Typ BHK 052
Typ BHK 052B
Typ BHK/K
Typ BHK/K EFV
INHALTSVERZEICHNIS
ZU DIESER ANLEITUNG ......................................................................................................................... 2
ÄNDERUNGEN ZUR VORHERGEHENDEN AUSGABE .............................................
............................. 2
SICHERHEITSBEZOGENE HINWEISE ...........
........................................................................................ 2
PRODUKTBEZOGENE SICHERHEITSHIN
WEISE .................................................................................. 2
ALLGEMEINE PRODUKTINFORMATION ....
........................................................................................... 3
BESTIMMUNGSGEMÄSSE VERWENDUNG ...........................................
............................................... 3
NICHT BESTIMMUNGSGEMÄSSE VERWENDU
NG ............................................................................... 3
QUALIFIKATION DER ANWENDER .........................
............................................................................... 4
AUFBAU .............................................
..................................................................................................... 4
VORTEILE UND AUSSTATTUNG.............................................
............................................................... 5
ANSCHLÜSSE .............................................
............................................................................................ 8
MONTAGE ...........................................
.................................................................................................. 10
DICHTHEITSKONTROLLE .............................................
....................................................................... 12
INBETRIEBNAHME ...........................................
.................................................................................... 12
FEHLERBEHEBUNG .............................................
................................................................................ 13
WARTUNG ...........................................
................................................................................................. 15
AUSTAUSCH ....................................
..................................................................................................... 15
INSTANDSETZUNG ...........................................
................................................................................... 15
AUSSERBETRIEBNAHME .............................................
....................................................................... 15
ENTSORGEN ...........................................
............................................................................................. 15
TECHNISCHE DATEN ...........................................
................................................................................ 15
LISTE DER ZUBEHÖRTEILE ...........................................
...................................................................... 15
GEWÄHRLEISTUNG .............................................
................................................................................ 16
TECHNISCHE ÄNDERUNGEN .......................................
....................................................................... 16

Table of Contents

Questions and Answers

  • T
    Todd DavisAug 5, 2025
    What to do if I smell gas with my GOK Controller?
    • R
      Roy Klein PhDAug 5, 2025
      If you smell gas when using your GOK Controller, immediately close the gas supply and avoid using any electrical switches or phones within the building. Ensure the rooms are well-ventilated. Then, shut down the LPG system and contact a specialized company for assistance, as leaking LPG is extremely flammable and can cause explosions.
  • T
    Tracy MendozaAug 12, 2025
    Why is there no gas flow in my GOK Controller?
    • K
      Kimberly DavisAug 12, 2025
      If there is no gas flow in your GOK Controller, first ensure that the gas cylinder valve or shut-off fittings are open. Also, check if the Safety overpressure shut-off valve (OPSO) or the UPSO / EFV is closed; if so, follow the steps for restarting them. If the filter sieve in the input connection is dirty, the pressure regulator should be sent to the manufacturer for cleaning.
  • M
    Michael CampbellAug 20, 2025
    What to do if OPSO cannot be unlocked in GOK Controller?
    • B
      brandonsmithAug 20, 2025
      If the OPSO on your GOK Controller cannot be unlocked, it may indicate that the regulator membrane is damaged. In this case, the pressure regulator is defective and needs to be replaced.
  • J
    Jonathan MurrayAug 27, 2025
    How to fix abnormal flame pattern of non-adjustable pressure regulator in GOK Controller?
    • Y
      ymooreAug 27, 2025
      If the flame pattern of your GOK Controller's non-adjustable pressure regulator is abnormal, compare the nominal outlet pressure with the nominal connection pressure. If they don't match, replace either the pressure regulator or the gas appliance. Measure the outlet pressure; if it's not within the specified limits, check the system configuration and clean the filter screen. If the pressure regulator is defective, replace it.

Summary

Safety Advice

Product-Related Safety Advice

Specific safety instructions related to product hazards, including DANGER, WARNING, and CAUTION levels.

Escaping Liquid Petroleum Gas

Hazards and safety measures for flammable LPG, emphasizing flammability and explosion risks.

Intended Use

User Qualification

Advantages and Equipment

Risk of Asphyxiation from Gas Leaks

Hazards of gas leaks in enclosed spaces and necessary precautions for ventilation.

Safety Overpressure Shut-off Valve (OPSO) Option

Operation and response of the OPSO safety device for monitoring outlet pressure.

Under-Pressure Shut-off Device (UPSO) Option

Functionality of the UPSO safety device and events that can trigger it.

Excess Flow Valve (EFV) Option

Emergency Supply Connector Option

Connections

Connections (Continued)

Assembly

Installation Guidelines

Leak Check

Leak Check Procedure

Step-by-step guide for checking all connections for leaks using a foaming agent.

Start-Up

Troubleshooting

Restarting OPSO;UPSO

Step-by-step guide to manually reset the OPSO/UPSO safety device after activation.

Restarting UPSO;EFV

Replacement

Flood Damage Warning

Warning about product damage, corrosion, and malfunctions caused by flooding.

Technical Data