Originalanleitung / Artikel-Nr. 01 153 52 b
Ausgabe 11.2016
Montage- und Bedienungsanleitung
Niederdruckregler Typ EN61-DS.2
zum E
inbau in Flüssiggasanlagen
INHALTSVERZEICHNIS
ZU DIESER ANLEITUNG ......................................................................................................................... 1
ALLGEMEINE PRODUKTINFORMAT
ION ............................................................................................... 1
SICHERHEITSBEZOGENE HINWEI
SE ................................................................................................... 2
PRODUKTBEZOGENE SICHERHEITSHIN
WEISE .................................................................................. 2
BESTIMMUNGSGEMÄSSE VERWENDUNG ................................
.......................................................... 2
NICHT BESTIMMUNGSGEMÄSSE VE
RWENDUNG ............................................................................... 3
QUALIFIKATION DER ANWENDER ...........
............................................................................................. 3
AUFBAU ...............................
................................................................................................................... 3
VORTEILE UND AUSSTATTUNG.........................
................................................................................... 3
ANSCHLÜSSE ...............................
.......................................................................................................... 4
MONTAGE ................................
............................................................................................................... 4
DICHTHEITSKONTROLLE ...............................
....................................................................................... 6
INBETRIEBNAHME ................................
................................................................................................. 6
BEDIENUNG ...............................
............................................................................................................. 6
FEHLERBEHEBUNG ...............................
................................................................................................ 6
WARTUNG ................................
.............................................................................................................. 7
AUSTAUSCH ................................
........................................................................................................... 7
INSTANDSETZUNG ................................
................................................................................................ 8
AUSSERBETRIEBNAHME ...............................
....................................................................................... 8
ENTSORGEN ................................
.......................................................................................................... 8
TECHNISCHE DATEN ................................
............................................................................................. 8
GEWÄHRLEISTUNG ...............................
................................................................................................ 8
TECHNISCHE ÄNDERUNGEN .........................
....................................................................................... 8
ZU DIESER ANLEITUNG
Diese Anleitung ist ein Teil des Produktes.
Für den bestimmungsgemäßen Betrieb und zur Einhaltung der Gewährleistung
ist diese Anleitung zu beachten und dem Betreiber auszuhändigen.
Während der gesamten Benutzung aufbewahren.
Zusätzlich zu dieser Anleitung sind die nationalen Vorschriften, Gesetze und
Installationsrichtlinien zu beachten.
ALLGEMEINE PRODUKTINFORMATION
Der Druckregler hält den auf dem Typschild angegebenen Ausgangsdruck konstant,
unabhängig von Schwankungen des Eingangsdruckes und Änderungen von Durchfluss und
Temperatur innerhalb festgelegter Grenzen.

Table of Contents

Questions and Answers

Summary

About the Manual

General Product Information

Explains how the pressure regulator maintains constant outlet pressure regardless of input fluctuations within defined limits.

Safety Advice

Safety Symbols and Hazard Levels

Explains the safety alert symbol and hazard words like DANGER, WARNING, CAUTION, and NOTICE used in the manual.

Product-Specific Safety

Details risks associated with escaping LPG, such as flammability, explosion potential, and skin contact.

Intended Use

Inappropriate Use

User Qualification

Product Design

Two-Stage Safety Regulator (S2 SR)

Explains the S2SR's function in protecting against high pressures and its display unit indication.

Thermal Shut-Out Device (TAE)

Describes the optional TAE's function to block gas supply at high temperatures, requiring replacement if triggered.

Connections

Assembly

Installation and Safety Notes

Handling Metal Chips

Warns about eye injuries from metal chips and advises wearing safety goggles during installation.

Connection Tightening

Warns about explosion risks from leaks and advises tightening connections only when not pressurized.

Filter Installation Recommendation

Recommends installing a gas filter to trap dirt particles and prevent wear on sensitive components.

Leak Testing

Start-Up Procedure

Operation

Troubleshooting

Gas Smell; Leaking LPG

Actions for gas smell include closing supply, ventilating, and contacting a specialist.

Abnormal Flame Pattern

Advise comparing outlet pressure to nominal pressure or checking system configuration/regulator.

Safety Regulator (S2 SR) Display RED

Actions include switching off gas, allowing short gas bursts for equalization, or replacing the regulator.

No Gas Flow

Possible causes include closed valves, responded thermal cut-out, or dirty filter sieve; actions provided.

Maintenance and Replacement

Maintenance

States the product is maintenance-free upon proper assembly and operation.

Replacement

Recommends replacing worn or damaged parts and suggests a 10-year replacement interval.

Restoration and Shut-Down

Restoration

If troubleshooting fails, the product must be sent to the manufacturer; warranty excludes unauthorized interference.

Shut-Down

Procedures for closing gas supply and shut-off fittings, and securing free connections.

Disposal

Technical Data

Warranty Information

Technical Changes

Summary

About the Manual

General Product Information

Explains how the pressure regulator maintains constant outlet pressure regardless of input fluctuations within defined limits.

Safety Advice

Safety Symbols and Hazard Levels

Explains the safety alert symbol and hazard words like DANGER, WARNING, CAUTION, and NOTICE used in the manual.

Product-Specific Safety

Details risks associated with escaping LPG, such as flammability, explosion potential, and skin contact.

Intended Use

Inappropriate Use

User Qualification

Product Design

Two-Stage Safety Regulator (S2 SR)

Explains the S2SR's function in protecting against high pressures and its display unit indication.

Thermal Shut-Out Device (TAE)

Describes the optional TAE's function to block gas supply at high temperatures, requiring replacement if triggered.

Connections

Assembly

Installation and Safety Notes

Handling Metal Chips

Warns about eye injuries from metal chips and advises wearing safety goggles during installation.

Connection Tightening

Warns about explosion risks from leaks and advises tightening connections only when not pressurized.

Filter Installation Recommendation

Recommends installing a gas filter to trap dirt particles and prevent wear on sensitive components.

Leak Testing

Start-Up Procedure

Operation

Troubleshooting

Gas Smell; Leaking LPG

Actions for gas smell include closing supply, ventilating, and contacting a specialist.

Abnormal Flame Pattern

Advise comparing outlet pressure to nominal pressure or checking system configuration/regulator.

Safety Regulator (S2 SR) Display RED

Actions include switching off gas, allowing short gas bursts for equalization, or replacing the regulator.

No Gas Flow

Possible causes include closed valves, responded thermal cut-out, or dirty filter sieve; actions provided.

Maintenance and Replacement

Maintenance

States the product is maintenance-free upon proper assembly and operation.

Replacement

Recommends replacing worn or damaged parts and suggests a 10-year replacement interval.

Restoration and Shut-Down

Restoration

If troubleshooting fails, the product must be sent to the manufacturer; warranty excludes unauthorized interference.

Shut-Down

Procedures for closing gas supply and shut-off fittings, and securing free connections.

Disposal

Technical Data

Warranty Information

Technical Changes

GOK EN61-DS.2 Specifications

General IconGeneral
BrandGOK
ModelEN61-DS.2
CategoryController
LanguageEnglish

Related product manuals