Goldak 902 - Locating Hidden Valve Caps

Goldak 902
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. Locating Hidden Valve Caps and Manholes.
The 902 receiver incorporates a feature that makes locating
masses of metal buried below the surface simple and con-
venient. Activating the LOCATE MASS button reconfigures
the receiver antenna, making it sensitive to nearby metallic
masses, such as manholes and valve caps. A continuous
tone emerges from the receiver which changes frequency
when brought near a metallic mass. Details on using this
feature follow here (see Figure 15).
a) At any time while you are tracing a line, you may press the
LOCATE MASS button. Once set to locate masses, the
receiver outputs a continuous tone.
b) Move with the receiver held flat to the surface beneath
which you a searching for a mass. In this mode, the
receiver is only sensitive to about 18 to 24 inches, so you
must search with the receiver held close to the surface.
Model 902 Pipe & Cable Locator
25