EasyManua.ls Logo

Golden Blount SUPER-FIRE SF3624-TV User Manual

Default Icon
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSTALLATION AND OPERATING INSTRUCTIONS
GOLDEN BLOUNT
SUPER-FIRE
MODEL SF3624-TV TOP-VENT FIREPLACE
CSA APPROVED FOR NATURAL GAS OR PROPANE GAS
IMPORTANT! Read all instructions carefully before starting
installation. Failure to follow these instructions may result in
property damage, personal injury or possible loss of life.
WARNING: If the information in these
instructions is not followed exactly, a
fire or explosion may result causing
property damage, personal injury or
death.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL
GAS:


do not use any phone in your


from a neighbor’s phone. Follow the
gas supplier’s instructions.

supplier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
The Flue Damper must be in the
full open position when burning the
gas logs.
This fireplace is to be burned only
with the gas log set supplied with the
fireplace. Burning other items could
cause a fire hazard or injury.
For best results, Natural Gas pressure
should be 7" to 12" W.C. and 11" W.C.
for Propane Gas.
To simulate real wood burning, the gas
burner is designed to burn a yellow
flame. It is normal for the logs to soot-
up. The soot can be easily removed
with a vacuum cleaner or soft brush.
Check the label on the firebox to
assure the proper gas type. Never
use anything but the correct gas type
for your fireplace.
This appliance complies with National
Safety and is tested and listed to ANSI
Z21.50b - 2009 as Vented Gas fireplaces.
Installation must conform to local codes.
In the absence of local codes, installation
must conform with the current National
Fuel Gas Code, ANSI Z223.1.
Massachusetts State Code requires
damper to be welded open or removed.
2/05
MANUFACTURED BY:
4301 WESTGROVE DRIVE
ADDISON TX. 75001
INSTALLER/CONSUMER RETAIN THIS APPLIANCE
MANUAL WITH THE INSTALLED APPLIANCE
Question and Answer IconNeed help?

Do you have a question about the Golden Blount SUPER-FIRE SF3624-TV and is the answer not in the manual?

Golden Blount SUPER-FIRE SF3624-TV Specifications

General IconGeneral
BrandGolden Blount
ModelSUPER-FIRE SF3624-TV
CategoryIndoor Fireplace
LanguageEnglish

Summary

Safety and Warnings

Important Installation Precautions

Critical instructions to follow before starting installation to prevent damage or injury.

Gas Leak Safety Procedures

Actionable steps to take if you smell gas, emphasizing safety and external notification.

General Safety Guidelines

Prohibits storing flammable liquids, stresses qualified installation, and mentions damper position.

Building Codes and Safety Standards

General Appliance Information

Details on the appliance's design, model, and fuel type compatibility.

Required Installation Clearances

Specifies minimum clearance dimensions for the firebox and surrounding areas.

Gas Piping and Pressure Requirements

Installation Instructions

Bedroom Installation Requirements

Guidelines for installing the fireplace in a bedroom, including unconfined space volume.

Mounting and Framing Guidelines

Information on suitable mounting surfaces and construction of fireplace framing.

Location and Environmental Precautions

Warnings about appliance placement, proximity to combustibles, and operating in negative pressure environments.

Chimney and Vent System Installation

Chimney Height and Offset Rules

Guidelines for chimney height, offset angles, and specialized caps for optimal draft.

Alternative Venting Solutions

Details on contacting ENERVEX for custom venting systems and compliance with codes.

Component Installation Procedures

Outside Air Kit and Gas Line Connection

Instructions for installing the outside air kit and connecting the gas supply line.

Wall Finishing and Hearth Extension

Guidance on finishing the wall around the fireplace and installing a hearth extension.

Gas Log Installation Steps

Steps for preparing the burner pan and placing the logs for the gas fireplace.

Refractory Panels and Diverter Installation

Refractory Brick Panel Installation

Procedure for field-installing the massive refractory brick panels inside the firebox.

Downdraft Diverter Installation

Instructions for installing the downdraft diverter to prevent downdrafts affecting burner operation.

Exhaust Diverter Installation

Log Placement for SF3624TBF

Log Arrangement Instructions

Step-by-step guide for arranging the logs on the grate for optimal appearance and performance.

Optional Glass Door Installation

Glass Door Installation Steps

Instructions for installing the optional glass door tracks, springs, and doors.

Operating Guidelines (Millivolt Model)

Initial Startup and Purging

Procedure for initial lighting, including purging air from gas lines and pilot ignition.

Safety and Maintenance Recommendations

Warnings for children, maintenance checks, and turning off gas before servicing.

Operating Guidelines (Continued)

Initial Burn Odor and Flame Characteristics

Information about initial odors during first use and expected main burner flame characteristics.

Maintenance and Venting Checks

Guidance on pilot inspection, cleaning, and periodic examination of the venting system.

Lighting Instructions

Pre-Lighting Safety Checks

Critical safety steps before lighting, including smelling for gas and checking appliance condition.

Pilot and Burner Ignition Procedure

Step-by-step guide for lighting the pilot light using the piezo ignitor and turning on the main burner.

Turning Off Gas and Propane Warnings

Procedure to Turn Off Gas

Steps for safely turning off the gas supply to the appliance via the control knob.

LPG (Propane) Specific Warnings

Critical safety precautions for installations using LPG, focusing on leak detection and emergency response.

Troubleshooting (Millivolt Model)

Ignitor Not Lighting Pilot

Diagnosing and correcting issues where the spark ignitor fails to light the pilot.

Troubleshooting Continued (Millivolt Model)

Pilot Will Not Stay Lit

Troubleshooting steps for a pilot light that extinguishes after ignition.

Troubleshooting (Burner Issues)

Pilot Lit, No Main Burner Operation

Diagnosing why the main burner fails to ignite or operate when the pilot is lit.

Pilot and Main Burner Extinguish During Operation

Addressing issues where both pilot and main burner go out while the appliance is in use.

Operating Guidelines (STP-Spark to Pilot Model)

Initial Startup and Air Purging

Procedure for initial lighting, purging air from lines, and igniting the pilot with the spark device.

Initial Burn Odor and Flame Sensor Check

Information about initial odors during first use and checking flame sensor engagement with pilot.

Wiring Diagram (STP-Spark to Pilot Model)

Lighting Instructions (Elec. Spark to Pilot)

Pre-Lighting Safety and Battery Check

Safety checks before lighting, including turning off the switch and checking batteries.

Pilot Ignition and Burner Operation

Procedure for starting the appliance using the automatic ignition device and turning on the burner.

Troubleshooting (STP-Spark to Pilot Model)

Ignitor Not Sparking or Pilot Not Lighting

Diagnosing issues with the ignitor not sparking or the pilot light failing to ignite.

Troubleshooting Continued (STP-Spark to Pilot Model)

Pilot Flame Issues and Gas Supply

Troubleshooting pilot flame problems, venting issues, and gas supply concerns.

Replacement Parts

Warranty Information

Two Year Limited Warranty Details

Details the terms and conditions of the limited warranty for the fireplace and its components.