This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman
does not assume any responsibility for property damage or personal injury due to improper
service procedures or services performed by an unqualified person.
Copyright © 2015-2017 Goodman Manufacturing Company, L.P.
ComfortNet
ASXC, DSXC, and GSXC Condensing Units,
ASZC, DSZC and GSZC
Split System Heat Pumps
with R-410A Refrigerant
Blowers, Coils, & Accessories
Service Instructions
is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company, L.P., Houston, TX. All rights reserved.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Goodman ComfortNet GSZC16036 and is the answer not in the manual?

Goodman ComfortNet GSZC16036 Specifications

General IconGeneral
Cooling Capacity (BTU)36, 000
Heating Capacity (BTU)36, 000
SEER Rating16
HSPF Rating9
RefrigerantR-410A
Compressor TypeTwo-Stage
Stages2
Voltage (V)208/230
Phase1

Summary

Service Instructions

IMPORTANT INFORMATION

SAFE REFRIGERANT HANDLING

PRODUCT IDENTIFICATION

PRODUCT DESIGN

SYSTEM OPERATION

DEFROST CYCLE - COMFORTNETTM MODELS

Explains the defrost cycle control mechanism for ComfortNet models.

TROUBLESHOOTING CHART

SERVICING

S-1 CHECKING VOLTAGE

Procedure for measuring system voltage and locked rotor voltage.

Network Troubleshooting

Troubleshooting the ComfortNet system network using on-board tools.

PCBJA104 AIR HANDLER DIAGNOSTIC CODES

Table detailing diagnostic codes for PCBJA104 air handler controls.

S-17 CHECKING COMPRESSOR

Safety warnings and procedures for checking hermetic compressors.

S-17C UNLOADER TEST PROCEDURE

Method to verify the operation of the unloader test procedure.

S-26 TESTING TEMPERATURE SENSORS (COMFORTNET READY MODELS ONLY)

Procedure for testing outdoor and indoor coil temperature sensors.

Troubleshooting Motor Control Circuits

Guidance on troubleshooting motor control circuits using system tools.

S-101 LEAK TESTING (NITROGEN OR NITRO-GEN-TRACED)

Methods for leak testing refrigeration systems using nitrogen.

EXPANSION VALVE SYSTEM

Guidelines for charging units with non-adjustable TXVs.

S-104 CHECKING COMPRESSOR EFFICIENCY

Procedure to diagnose compressor inefficiency by checking scroll flanks.

CHECKING COMPRESSOR EFFICIENCY

Procedure to diagnose compressor inefficiency by checking scroll flanks.

PCBJA101- PCBJA102 AIR HANDLER DIAGNOSTIC CODES

Table detailing diagnostic codes for PCBJA101/102 air handler controls.

S-16H ECM CFM ADJUSTMENTS AVPTC/MBVC

Guide for adjusting ECM blower CFM using dipswitches on AVPTC/MBVC models.

S-17A RESISTANCE TEST

Procedure for testing compressor winding resistance.

S-40A AVPTC/MBVC ELECTRONIC BLOWER/HEATER CONTROL

Details the electronic control for AVPTC/MBVC blowers and heaters.

SEQUENCE OF OPERATION AVPTC/MBVC with ASXC/DSXC Condenser and CTK0* Communicating Themostat

Describes the sequence of operation for systems with these components.

S-61A CHECKING HEATER LIMIT CONTROL(S)

Procedure for checking heater limit controls for proper function.

S-102 EVACUATION

Procedure for evacuating the system to remove air and moisture.

Units Equipped with Adjustable Expansion Valves should be charged by Subcooling and Superheat adjusted only if necessary.

Procedures for charging units with adjustable TXVs using subcooling and superheat.

S-115 COMPRESSOR BURNOUT

Steps to diagnose and handle a compressor burnout situation.

S-17B GROUND TEST

Procedure for testing compressor windings for ground faults.

S-21 CHECKING REVERSING VALVE AND SOLENOID

Steps to check the reversing valve for proper operation and position.

Data Line Voltage Troubleshooting and Bias Switches

Troubleshooting data line voltage and bias switch settings for communication.

S-100 REFRIGERATION REPAIR PRACTICE

General practices for refrigeration system repair, including brazing.

S-103 CHARGING

Steps for charging the system with the correct refrigerant amount.

S-10A COPELAND COMFORT ALERTTM - UNITARY (UC) CONTROL DIAGNOSTICS

Overview of Copeland Comfort Alert diagnostics integrated into the UC control.

S-24 TESTING DEFROST CONTROL

Procedure for testing the defrost control unit.

4.0 Defrost Operation

Explains the defrost cycle operation and its control.