SYSTEM OPERATION
24
a media air lter or electronic air cleaner can be used as
the requested lter. Refer to the following minimum lter
requirement charts for determination of the minimum lter
area to ensure proper unit performance.

This furnace has provisions for the installation of return air
lters at the counterow top return. Refer to Minimum Filter
Area tables to determine lter area requirement.
 Filters can also be installed elsewhere in the duct
system such as a central return.

Filter(s) must be installed external to the furnace casing for
horizontal installations. For most installations it is preferable
to use a central return with lters installed in the duct behind
the return air grill. In this way lter replacement is relatively
simple by merely removing the grille, rather than going into
the attic or crawl space.


The external lter rack kit is intended to provide a location
external to the furnace casing, for installation of a permanent
lter on upow model furnaces. The rack is designed to mount
over the indoor blower compartment area of either side panel,
and provide lter retention as well as a location for attaching
return air ductwork.