EasyManua.ls Logo

Goodman GMH80903BN Series - Product Design: Switch Settings and Limits; Pressure Switch Trip Points and Usage; Primary Limit Settings; Rollout and Auxiliary Limit Switches

Goodman GMH80903BN Series
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
PRODUCT DESIGN
For installaions in Canada, the GMH8 furnace is certified only to 4,500 ft.
* Negative pressure readings are in inches of water column (*w.c.)
MODEL
TRIP POINT
ID BLOWER
PRESSURE
SWITCH
ID BLOWER
PRESSURE
SWITCH
PART #
MODEL
TRIP POINT
ID BLOWER
PRESSURE
SWITCH
ID BLOWER
PRESSURE
SWITCH
PART #
GMH80453AN**
-0.60 B1370142
GMH80453AN**
-0.60 B1370142
GMH80703AN**
-0.60 B1370142
GMH80703AN**
-0.60 B1370142
GMH80704BN**
-0.60 B1370142
GMH80704BN**
-0.47 B1370176
GMH80903BN**
-0.60 B1370142
GMH80903BN**
-0.75 B1370179
GMH80904BN**
-0.60 B1370142
GMH80904BN**
-0.75 B1370179
GMH80905CN**
-0.70 B1370158
GMH80905CN**
-0.60 B1370142
GMH81155CN**
-0.70 B1370158
GMH81155CN**
-0.70 B1370158
GMH81405DN**
-0.75 013070159
GMH81405DN**
-0.60 013070142
PRESSURE SWITCH TRIP POINTS
AND USAGE CHART
SQUARE NOSE ROUND NOSE
PRESSURE SWITCH TRIP POINTS
AND USAGE CHART
Part Number
B1370145
Open Setting (°F) 300
GMH80453AN**
2
GMH80703AN**
2
GMH80704BN**
2
GMH80903BN**
2
GMH80904BN**
2
GMH80905CN**
2
GMH81155CN**
2
GMH81405DN**
2
ROLLOUT LIMIT SWITCHES
Part Number
B1370155
Open Setting (°F) 120
GMH80453AN**
1
GMH80703AN**
1
GMH80704BN**
1
GMH80903BN**
1
GMH80904BN**
1
GMH80905CN**
1
GMH81155CN**
1
GMH81405DN**
1
AUXILIARY LIMIT SWITCHES
Part Number B1370190 B1370187 B1370188 B1370198 B1370189
Open Setting (°F) 210 160 170 150 200
GMH80453AN**
1 --- --- --- ---
GMH80703AN**
--- 1 --- --- ---
GMH80704BN**
--- --- 1 --- ---
GMH80903BN**
--- --- --- 1 ---
GMH80904BN**
--- --- 1 --- ---
GMH80905CN**
--- --- --- --- 1
GMH81155CN**
--- --- --- 1 ---
GMH81405DN**
--- --- --- 1 ---
T.O.D. PRIMARY LIMIT