Goodman GMVC95 - Specifications

Goodman GMVC95
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SS-GMVC95 www.goodmanmfg.com 3
product speciFications
speciFications
GMVC95
0453BXAA
GMVC95
0704CXAA
GMVC95
0905DXAA
GMVC95
1155DXAA
GCVC9
0704CXAA
GCVC9
0905DXAA
GCVC9
1155DXAA
Heating Capacity
High Fire Input¹ 46,000 69,000 92,000 115,000 69,000 92,000 115,000
High Fire Output¹ 45,000 67,000 90,000 109,000 65,000 87,000 109,000
Low Fire Input¹ 32,000 48,000 64,000 80,000 48,000 64,000 80,000
Low Fire Output¹ 30,800 46,400 61,700 77,400 45,000 60,100 77,400
AFUE² 95 95 95 95 93 93 93
Tons AC @ 0.5” ESP 1.5 - 3.0 1.5 - 4.0 2.0 - 5.0 2.0 - 5.0 1.5 - 4.0 2.0 - 5.0 2.0 - 5.0
Temperature Rise Range (°F) 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60 40-70
Circulator Blower
Size (D x W) 10” x 8” 10” x 10” 11” x 10” 11” x 10” 10” x 10” 11” x 10” 11” x 10”
Horespower @ 1050 RPM ½ ¾ 1 1 ¾ 1 1
Speed Variable Variable Variable
Vent Diameter³ 2” 2” 3” 3” 2” 3” 3”
No. of Burners 2 3 4 5 3 4 5
Disposable Filter (in²) 288 384 480 486 384 480 486
Electrical Data
Min. Circuit Ampacity (amps)
4
11.3 14.1 17.9 17.9 14.1 17.9 17.9
Max. Overcurrent Protection
5
15 amps 15 amps 20 amps 20 amps 15 amps 20 amps 20 amps
Ship Weight (lbs) 133 135 172 175 135 172 175
¹ Natural Gas BTU/h
² DOE AFUE based upon Isolated Combustion System (ICS)
³ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the ue outlet (required). Vent pipe must be
either 2” or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional
Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.
4
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with Na-
tional Electrical Codes. Extensive wire runs will require larger wire sizes.
5
Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit
breakers of the same size as noted.
Notes:
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
Gas Service Connection ½” FPT
Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all exist-
ing local codes.