7
PRODUCT DIMENSIONS DC96VC
RIGHT SIDE VIEW
TOP VIEW FRONT VIEW
A
34 ½
4⅛
11⅜
14¾
25⅛
28¾
C
6⅞
6⅞
11⅜
14⅞
14¾
25⅛
3½
2½
2
1⅞
2⅝
23
14
1⅜
1½
1⅝
E
UNFOLDED
FLANGES
D
FOLDED FLANGES
18 ⅛
FOLDED FLANGES
20 ⅛
UNFOLDED FLANGS
2⅝
1 ⅞
2½
6½
2
AIR
DISCHARGE
SIDE CUT-OU T
SIDE CUT-OU T
AIR
DISCHARGE
LEFT SIDE VIEW
FRONT VIEW
RIGHT SIDE VIEW
LOW VOLTAGE
ELECTRICAL OUTLET
ALTERNATE GAS
SUPPLY LOCATION
HIGH VOLTAG E
ELECTRICAL
OUTLET
STANDARD DRAIN TRAP
CONNECTION
¾ PVC
LEFT SIDE EXTERIOR
DRAIN TRAP HOLE S
ALTERNATE
GAS SUPPLY
LOCATIO N
ALTERNATE VENT/
FLUE LOCATION
HIGH VOLTAGE
ELECTRICAL
OUTLET
RIGHT SIDE EXTERIO R
DRAIN TRAP HOLES
LOW VOLTAGE
ELECTRICAL
OUTLET
Model A B C D E
*CVC960403BNA
17½" 14⅝" 14" 14½" 16"
*CVC960603BNA
17½" 14⅝" 14" 14½" 16"
*CVC960804CNA
21" 18⅛" 17½" 18" 19½"
*CVC961005CNA
21" 18⅛" 17½" 18" 19½"
*CVC961205DNA 24½”
21⅝" 21" 21½" 23"
Position Sides Rear Front Bottom Flue Top
0" 0" 3" NC 0" 1"
Horizontal 6" 0" 3" C 0" 6"
M