What to do if Goodman GSC13018 has too much air across indoor coil?
- CCharles DuranSep 23, 2025
If there is too much air across the indoor coil of your Goodman Air Conditioner, reduce the blower speed.
What to do if Goodman GSC13018 has too much air across indoor coil?
If there is too much air across the indoor coil of your Goodman Air Conditioner, reduce the blower speed.
What to do if Goodman Air Conditioner has overcharge of refrigerant?
If you have an overcharge of refrigerant in your Goodman Air Conditioner, recover part of the charge.
How to fix loose connection in Goodman Air Conditioner?
If your Goodman Air Conditioner has a loose connection, inspect the connection and tighten it.
How to test shorted or broken wires in Goodman GSC13018?
If your Goodman Air Conditioner has shorted or broken wires, test the circuits with an ohmmeter.
What to do if Goodman GSC13018 Air Conditioner has noncondensibles?
If your Goodman Air Conditioner has noncondensibles, recover the charge, evacuate, and recharge.
What to do if Goodman Air Conditioner has not enough air across indoor coil?
If there is not enough air across the indoor coil of your Goodman Air Conditioner, increase the blower speed and check the duct static pressure.
What to do if Goodman GSC13018 Air Conditioner has undersized liquid line?
If the liquid line is undersized in your Goodman Air Conditioner, replace the line.
What to do if Goodman GSC13018 has undersized suction line?
If the suction line is undersized in your Goodman Air Conditioner, replace the line.
How to test faulty fan relay in Goodman Air Conditioner?
If your Goodman Air Conditioner has a faulty fan relay, test the continuity of the coil and contacts.
How to test shorted or grounded compressor in Goodman GSC13018?
If your Goodman Air Conditioner compressor is shorted or grounded, test the motor windings.
Disconnect all power before servicing to prevent property damage, personal injury or death.
Refrigerants are heavier than air; avoid breathing them. Wear gloves and goggles.
Disconnect power. Use copper conductors and follow NEC/CEC codes.
Table lists common complaints, possible causes, symptoms, and test methods/remedies.
Disconnect all power before servicing to prevent property damage, personal injury or death.
Refrigerants are heavier than air; avoid breathing them. Wear gloves and goggles.
Disconnect power. Use copper conductors and follow NEC/CEC codes.
Table lists common complaints, possible causes, symptoms, and test methods/remedies.