How to check faulty transformer in Goodman Air Conditioner?
- MmdouglasSep 1, 2025
If your Goodman Air Conditioner has a faulty transformer, check the control circuit with a voltmeter.
How to check faulty transformer in Goodman Air Conditioner?
If your Goodman Air Conditioner has a faulty transformer, check the control circuit with a voltmeter.
How to test faulty thermostat in Goodman GSC13024?
If the thermostat is faulty in your Goodman Air Conditioner, test the continuity of the thermostat and wiring.
How to test open overload in Goodman Air Conditioner?
If your Goodman Air Conditioner has an open overload, test the continuity of overloads.
What to do if Goodman Air Conditioner has noncondensibles?
If your Goodman Air Conditioner has noncondensibles, recover the charge, evacuate, and recharge.
How to test shorted or broken wires in Goodman GSC13024?
If your Goodman Air Conditioner has shorted or broken wires, test the circuits with an ohmmeter.
How to fix loose connection in Goodman GSC13024 Air Conditioner?
If your Goodman Air Conditioner has a loose connection, inspect the connection and tighten it.
What to do if Goodman Air Conditioner has overcharge of refrigerant?
If you have an overcharge of refrigerant in your Goodman Air Conditioner, recover part of the charge.
Cooling Capacity | 24, 000 BTU/h |
---|---|
SEER Rating | 13 |
Compressor Type | Scroll |
Refrigerant Type | R-410A |
Tonnage | 2 tons |
Voltage | 208/230 V |
Phase | 1 |
Sound Level | 76 dB |
Unit shipped with nitrogen/helium holding charge only; must be evacuated and charged.
Units with holding charge are for component replacement on existing systems.
Units must only be used as replacement components for pre-2010 installed systems.
Steps for connecting gauges, measuring temperature, and adjusting refrigerant charge.
Warning about high voltage and the need to disconnect power before servicing.
Specifies required technician level and provides warranty information.
Details shipping inspection, regulatory compliance, and installation clearances.
Guidelines for rooftop installation and safe handling of refrigerants.
Covers dangers of refrigerant exposure, cold, and EPA regulations.
Precautions for cylinders, system openings, and oil moisture.
Proper methods for routing lines, insulating them, and preventing contact.
Steps for cutting, cleaning, and preparing refrigerant tubing.
Steps for brazing refrigerant lines, including heat control and joint preparation.
Guidelines for leak testing using nitrogen and safety precautions.
Method for pressure testing the system using nitrogen and soapy water.
Steps for evacuating the system to 250 microns or less.
Warning about high voltage and proper wiring practices.
Guidelines on wire sizing for voltage drop and using copper conductors.
Instructions for opening service valves and tightening caps.
Guidance on adding refrigerant amount shown in table for the unit.
Procedure for adjusting charge on fixed orifice systems using superheat.
Procedure for adjusting TXV systems based on subcooling and superheat.
Table listing complaints, possible causes, and test methods.