AHRI Ratings AHRI Ratings
44 www.goodmanmfg.com SS-GSX13
SS-GSX13 www.goodmanmfg.com 45
Outdoor
Unit
Indoor Units Cooling Ratings
CFM AHRI #
Coils/Air Handlers Furnaces Total¹ Sens.¹ SEER² EER³
GSX13
0611A*
(cont.)
CHPF4860D6D*+MBVC2000**-1A*+TXV 57,000 39,000 14.0 11.5 1,575 5586773
CHPF4860D6D*+TXV A*VC80805C*B* 56,000 38,500 14.0 11.5 1,520 5586776
CHPF4860D6D*+TXV A*VC81005C*B* 56,500 38,500 14.0 11.5 1,520 5586779
CHPF4860D6D*+TXV G*E80805C*B* 56,000 38,500 14.0 11.5 1,550 5586802
CHPF4860D6D*+TXV G*E81005C*B* 56,000 38,500 14.0 11.5 1,525 5586805
CHPF4860D6D*+TXV G*VC80805C*B* 56,000 38,500 14.0 11.5 1,520 5586808
CHPF4860D6D*+TXV G*VC81005C*B* 56,500 38,500 14.0 11.5 1,520 5586811
CHPF4860D6D*+TXV A*EH800805C*A* 56,000 38,500 14.0 11.5 1,550 6944966
CHPF4860D6D*+TXV A*EH801005C*A* 56,000 38,500 14.0 11.5 1,525 6944968
CHPF4860D6D*+TXV A*VC961005CNA* 56,000 38,500 13.5 11.0 1,520 7354204
CHPF4860D6D*+TXV A*VC961205DNA* 56,000 38,500 14.0 11.5 1,545 7354205
CHPF4860D6D*+TXV A*VM971005CNA* 56,000 38,500 13.5 11.0 1,520 7354206
CHPF4860D6D*+TXV A*VM971205DNA* 56,000 38,500 14.0 11.5 1,545 7354207
CHPF4860D6D*+TXV G*VC961005CNA* 56,000 38,500 13.5 11.0 1,520 7354208
CHPF4860D6D*+TXV G*VC961205DNA* 56,000 38,500 14.0 11.5 1,545 7354209
CHPF4860D6D*+TXV G*VM971005CNA* 56,000 38,500 13.5 11.0 1,520 7354210
CHPF4860D6D*+TXV G*VM971205DNA* 56,000 38,500 14.0 11.5 1,545 7354211
CHPF4860D6D*+TXV G*EC961205DNA* 56,000 38,500 14.0 11.5 1,525 7365329
CHPF4860D6D*+TXV A*EC961205DNA* 56,000 38,500 14.0 11.5 1,525 7365437
CSCF4860N6D*+EEP 55,000 37,600 13.0 11.0 1,500 5589903
CSCF4860N6D*+MBVC2000**-1A* 56,000 38,500 13.5 11.5 1,575 5589906
CSCF4860N6D*+MBVC2000**-1A*+TXV 56,000 38,500 14.0 11.5 1,575 5586690
CSCF4860N6D*+TXV G*E80805C*B* 54,500 37,400 13.0 11.0 1,550 5586829
CSCF4860N6D*+TXV A*VC80805C*B* 56,500 38,500 13.5 11.5 1,520 5589909
CSCF4860N6D*+TXV A*VC81005C*B* 55,500 38,000 13.5 11.0 1,520 5589912
CSCF4860N6D*+TXV G*E81005C*B* 55,500 38,000 13.5 11.0 1,525 5589933
CSCF4860N6D*+TXV G*VC80805C*B* 56,500 38,500 13.5 11.5 1,520 5589936
CSCF4860N6D*+TXV G*VC81005C*B* 55,500 38,000 13.5 11.0 1,520 5589939
CSCF4860N6D*+TXV A*EH800805C*A* 54,500 37,400 13.0 11.0 1,550 6944974
CSCF4860N6D*+TXV A*EH801005C*A* 55,500 38,000 13.5 11.0 1,525 6944976
CSCF4860N6D*+TXV A*VC961005CNA* 55,500 38,000 13.5 11.0 1,520 7354212
CSCF4860N6D*+TXV A*VC961205DNA* 55,500 38,000 13.5 11.0 1,545 7354213
CSCF4860N6D*+TXV A*VM971005CNA* 55,500 38,000 13.5 11.0 1,520 7354214
CSCF4860N6D*+TXV A*VM971205DNA* 55,500 38,000 13.5 11.0 1,545 7354215
CSCF4860N6D*+TXV G*VC961005CNA* 55,500 38,000 13.5 11.0 1,520 7354216
CSCF4860N6D*+TXV G*VC961205DNA* 55,500 38,000 13.5 11.0 1,545 7354217
CSCF4860N6D*+TXV G*VM971005CNA* 55,500 38,000 13.5 11.0 1,520 7354218
CSCF4860N6D*+TXV G*VM971205DNA* 55,500 38,000 13.5 11.0 1,545 7354219
¹ BTU/h
² Seasonal Energy Eciency Rao; Cered per AHRI 210/240 @ 80°F/ 67°F/ 95°F
³ Energy Eciency Rao @ 80°F/ 67°F/ 95°F
Notes
• Always check the S&R plate for electrical data on the unit being installed.
• When matching the outdoor unit to the indoor unit, use the piston supplied with the outdoor unit or that specied on the piston kit chart supplied with the indoor unit.
• EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S.
The Goodman brand gas furnace contains the EEP cooling me delay