EasyManua.ls Logo

Goodman MEC961205DN - Control Board Configuration; DIP Switch Settings

Goodman MEC961205DN
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
DIP SWITCH SETTINGS
PCBBF137 CONTROL BOARD DIP SWITCHES
1
2
3
S1
1
2
3
4
Cooling
CFM
Switches
Heating Fan
Off Delay
S3
S2
1
2
Heating
CFM
Switches
Thermostat
Selection
Switches
1
2
3
DIP
Switch
Group
DIP
Switch
Number
Purpose
Auto 1 OFF* 2 ON*
10 Minutes 1 ON 2 OFF
20 Minutes 1 ON 2 ON
2 Stage 1 OFF 2 OFF
90 Seconds 3 OFF 4 OFF
120 Seconds 3 OFF 4 ON
150 Seconds 3 ON* 4 OFF*
180 Seconds 3 ON* 4 ON
* = Factory Position
Function
S1
1, 2
3, 4
Heat
Staging /
Delay
Blower
Heat Off
Delay
PCBBF139 CONTROL BOARD DIP SWITCHES
S1
1
2
3
4
Cooling
CFM
Switches
HeatingFan
Off Delay
S3
S2
1
2
3
4
1
2
3
4
Heating
CFM
Switches
Continuous
Fan CFM
Switches
Thermostat
Selection
Switches
1234
2 Stage Stat OFF OFF
1 Stg Stat 10 min delay ON OFF
1 Stg Stat 20 min delay ON ON
Auto OFF* ON*
90 OFF OFF
120 OFF ON
150 ON* OFF*
180 ON ON
* FACTORY
SETTING
Dip Switch
Switch
Group
Function
S3
S3
Heating Fan
Off Delay
Purpose
Thermostat
Setup

Table of Contents

Related product manuals