EasyManua.ls Logo

Graco Fire-Ball 225 - User Manual

Graco Fire-Ball 225
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441
Copyright 2004, Graco Inc. is registered to I.S. EN ISO 9001
Installation and Operation
Fire-Ball
®
225, 300, and 425 Oil Pumps
For non-corrosive and non-abrasive oils
and lubricants only.
Mini Fire-Ball 225, 3:1
Parts 246775 and 248097
540 psi (3.7 MPa, 37 bar) Maximum Working Pressure
180 psi (1.24 MPa, 12.4 bar) Maximum Air Input Pressure
Fire-Ball 300, 5:1
Parts 203876, 203872, 203857, 204254, and 222087
900 psi (6.2 MPa, 62 bar) Maximum Working Pressure
180 psi (1.24 MPa, 12.4 bar) Maximum Air Input Pressure
Fire-Ball 425, 10:1
Parts 205626, 222065, and 222095
1800 psi (12.4 MPa, 124 bar) Maximum Working Pressure
180 psi (1.24 MPa, 12.4 bar) Maximum Air Input Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
309868B
http://gracomanual.com
Mascott Equipment Co
Portland Seattle Pasco
(800) 452-5019 (800) 481-7311 (888) 450-7867

Questions and Answers

  • M
    Michelle WareAug 9, 2025
    Why Graco Water Pump fails to operate?
    • A
      Ashley CampbellAug 9, 2025
      Your Graco Water Pump might fail to operate due to several reasons: inadequate air supply pressure or restricted air lines (increase air supply and/or clear restriction); closed or clogged valves (open and/or clear); clogged fluid lines, hoses, valves, etc. (relieve pressure and clear obstruction); damaged air motor (assess damage and service air motor); or exhausted fluid supply (refill and reprime or flush).
  • A
    amanda62Aug 14, 2025
    What to do if Graco Water Pump operates, but output is low on both strokes?
    • D
      Debbie EvansAug 14, 2025
      If your Graco Water Pump operates but the output is low on both strokes, it could be due to inadequate air supply or a restricted air line (increase air supply and /or clear restriction); closed or clogged valves (open and/or clear); exhausted fluid supply (refill fluid supply and reprime pump or flush); or clogged fluid lines, hoses, valves, etc. (relieve pressure and clear obstruction).
  • E
    elizabethsalazarAug 19, 2025
    Why Graco Fire-Ball 225 has erratic operation?
    • M
      Malik TorresAug 20, 2025
      Erratic operation of your Graco Water Pump can be caused by an exhausted fluid supply, so refill and reprime or flush. It may also be caused by a held open or worn intake valve or piston packings, so clear and service them.
  • J
    Jennifer GarrettAug 25, 2025
    What to do if Graco Fire-Ball 225 Water Pump operates, but output is low on upstroke?
    • C
      Casey BarnettAug 25, 2025
      If your Graco Water Pump operates, but the output is low on the upstroke, it is likely due to held open or worn piston packings. Clear and service them to resolve this issue.
  • T
    timothyallisonAug 29, 2025
    What to do if Graco Fire-Ball 225 operates, but output is low on downstroke?
    • J
      James AndersonAug 29, 2025
      If your Graco Water Pump operates, but the output is low on the downstroke, it is likely due to a held open or worn intake valve. Clear and service the valve.
  • A
    Anita GrahamSep 3, 2025
    Why Graco Water Pump has continuous air exhaust?
    • T
      Tracy FernandezSep 4, 2025
      Continuous air exhaust in your Graco Water Pump is caused by a worn or damaged air motor gasket or seal. Assess the wear or damage and service the air motor.