308874 13
On/Off Switch
Removal
1.
Relieve pressure; page 5.
2. Fig. 15. Remove five screws (307) and
cover (322).
3. Disconnect two wires (A) from ON/OFF
switch (309).
4. Press in on two retaining tabs on each side of
ON/OFF switch (309) and remove switch.
Installation
5. Install new ON/OFF switch (309) so tabs of switch
snap into place on inside of pressure control
housing.
6. Connect two wires (A) to ON/OFF switch.
7. Install pressure control cover (322) with five
screws (307).
Fig. 15
4 (Ref)
1 (Ref)
8711A
A309
302
303
E
D
313
310
304
315
316
317
304
312
311
310
318
319
301