Performance Charts
Performance Charts
Calculate Fluid Outlet Pressure
To calculate fluid outlet pressure (psi/MPa/bar) at
a specific fluid ow (gpm/lpm) and operating air
pressure (psi/MPa/bar), use the following instructions
and pum p data charts.
1. Locate desired ow along bottom of chart.
2. Follow vertic al line up to intersection with
selected uid outlet pressure curve. Follow left to
scale to read uid outlet pressure.
Calculate Pump Air Flow/Consump-
tion
To calculate pump air flow/consumption (scfm or
m
3
/min) at a specific fluid ow (gpm/lpm) and air
pressure (psi/Mpa/bar), use the following instructions
andpumpdatacharts.
1. Locate desired ow along bottom of chart.
2. Follow vertic al line up to intersection with
selected uid outlet pressure curve. Follow right
to scale to read air ow consumption.
Key: Air Pressure
A
100psi(0.7MPa,7bar)
B
70 psi (480 kPa, 4.8 bar)
C 40psi(280kPa,2.8bar)
45:1
Cycles Per Minute (cpm)
0
0
1.0
1.0
(3.8)
9
9
18
18
26
26
35
35
44
44
53
53
60
60
6000
6000
(42.0, 420)
5000
5000
(35.0, 350)
4000
4000
(28.0, 280)
3000
3000
(21.0, 210)
2000
2000
(14.0, 140)
1000
1000
(7.0, 70)
300
300
(8.5)
250
250
(7.0)
200
200
(5.6)
150
150
(4.2)
2.0
2.0
(7.6)
3.0
3.0
(11.4)
4.0
4.0
(15.2)
5.0
5.0
(19.0)
6.0
6.0
(22.7)
7.0
7.0
(26.5)
100
100
(2.8)
50
50
(1.4)
A
A
B
B
C
C
Fluid Pressure
psi (bar)
Fluid Flow gpm (lpm)
Air Flow
scfm (m
3
/min)
36