syncFURNACE OD Instruction & Installation Manual Rev 09 Pg. 1 of 81
Combination Gas-Fired Water Heater / Central Air Fan-coil Unit
Model >
IMPORTANT:
Be sure to read these instructions and fully understand prior to
installing this product.
The wetted surface of this product contacted by consumable water
contains less than one quarter of one percent (0.25%) of lead by
weight.
After installation, keep instructions near product for future reference.
This product must be installed and serviced by a properly trained &
licensed professional heating contractor FAILURE TO COMPLY
WILL VOID ALL PRODUCT WARRANTY
It is the responsibility of the installation contractor (upon completion
of the installation) to explain to the Owner or Operator of the heating
system how to correctly use as per these instructions and local code
requirements. Be sure that they are familiar with all heating system
equipment as well as safety devices, shut-down procedure(s) and
the need for professional service annually before the heating season
begins.
CAUTION:
After installation is complete it is the responsibility of the Owner or
Operator to ensure vent terminal(s) is cleared from snow, ice and/or
other debris.
Installation & Operation
Manual
www.gradientthermal.com
mOD-200
ANSI Z21.10.3 | CSA 4.3
UL 1995 | CSA C22.2 No. 236
Heating and Cooling Equipment
FURNACE + WATER HEATER

Table of Contents

Questions and Answers

  • O
    Olivia WattsAug 13, 2025
    What to do if the Gradient syncFURNACE mOD-200-05L flame fails during burner operation?
    • S
      Stephen PetersonAug 13, 2025
      If your Gradient Water Heater experiences flame failure during burner operation, verify the gas shut-off valve is open and the gas line is at the correct pressure. Also, ensure the gas valve test ports are closed and the differential pressure tube is properly connected. Check for a blocked chimney system and confirm the gas valve is correctly wired, receiving a signal from the ignition module. Inspect the wire harness continuity and check for combustion blower failure. The gas valve air/fuel mixture may need adjustment. Verify the chimney system lengths and vent termination locations, and check for trap pressure switch failure. Finally, verify the function of the ignition module and flame sensor/spark ignitor.
  • D
    Dylan FosterAug 20, 2025
    What to do if no flow is detected in Gradient syncFURNACE mOD-200-05L Water Heater after demand is turned on?
    • C
      Charles DrakeAug 20, 2025
      If your Gradient Water Heater shows no flow detected after demand is turned on, verify the pump is turning on and functioning properly. Ensure the system is pressurized and full of water, and that all air is purged from the system. Check piping valves to ensure they are all open and not blocked. Ensure piping and water is clean and free of dirt and debris and water meets the requirements listing in manual / warranty sheet. Check filters and/or dirt strainers and ensure no blockage; if blockage exists, clean. Check for a faulty flow switch, verifying electrical continuity and proper function of the paddle, and replace if necessary. Ensure wiring is properly terminated between sensor and syncFURNACE OD controller.
  • L
    lsmithAug 27, 2025
    What to do if flame is detected after gas-valve shut-off in Gradient syncFURNACE mOD-200-05L?
    • J
      Jonathan WeeksAug 28, 2025
      If you detect a flame after the gas valve shut-off in your Gradient Water Heater, verify the gas valve is wired correctly and receiving a signal to open from the ignition module, and check the wire harness continuity. If these steps don't resolve the issue, the gas valve has failed and must be replaced immediately.
  • S
    Stephanie StricklandAug 31, 2025
    What to do if Gradient syncFURNACE mOD-200-05L Water Heater fluid pressure is low?
    • A
      Allison PierceAug 31, 2025
      If your Gradient Water Heater detects low fluid pressure, check the cold water supply to ensure operation within safe characteristics and pressure limits. Make sure all valves are open, allowing water to enter and fill the system piping. Inspect filters and/or dirt strainers for blockages; clean if necessary. Check for a dirty pressure sensor, ensuring no debris or dirt is on the sensor port; clean gently with a nylon brush or replace if needed. Ensure wiring is properly terminated between the sensor and the syncFURNACE controller.
  • J
    Joseph HollandSep 4, 2025
    Why is the Gradient syncFURNACE mOD-200-05L Water Heater combustion blower RPM unstable?
    • C
      Christopher DavenportSep 4, 2025
      If your Gradient Water Heater combustion blower RPM is unstable, check for a partially or fully blocked chimney system. Also, check the wiring at the combustion blower, verifying both low voltage control and main power. Identify and replace any failed components, such as wiring, the combustion blower, or the controller.
  • R
    Raymond CarrilloSep 8, 2025
    How to troubleshoot no RPM from Comb Blwr at startup in Gradient syncFURNACE mOD-200-05L Water Heater?
    • D
      Daniel HernandezSep 8, 2025
      If there is no RPM from the combustion blower at startup for your Gradient Water Heater, check for a partially or fully blocked chimney system. Then, check the wiring at the combustion blower, verifying both low voltage control and main power. Identify and replace any failed component, such as the wiring, combustion blower, or controller.
  • C
    Cheryl ClayNov 15, 2025
    What to do if Gradient Water Heater burner fails to ignite due to ignition module lockout?
    • J
      jrobinsonNov 15, 2025
      If the Gradient Water Heater burner fails to ignite due to ignition module lockout, first verify the gas shut-off valve is open and the gas line is at the correct pressure. Ensure the gas valve test ports are closed and the differential pressure tube is properly connected. Check for a partially or fully blocked chimney system. Verify the gas valve is wired correctly and receiving a signal to open from the ignition module, and check the wire harness continuity. Check for combustion blower failure. The gas valve air/fuel mixture may require adjustment. Verify chimney system lengths and vent termination locations, and check for direct wind blowing onto the vent termination. Also, check for trap pressure switch failure. Finally, verify the function of the ignition module and flame sensor/spark...
  • P
    Patricia LongNov 23, 2025
    What to do if Gradient Water Heater has no power at ignition (Hi-Limit Safety Open)?
    • P
      Patrick WellsNov 23, 2025
      If your Gradient Water Heater has no power at ignition due to a high-limit safety open, identify which high-limit safety has opened and verify wire harness continuity. Note that safeties are connected to HIGH VOLTAGE LINE (115Vac). If the Vent Limit Switch is open, it indicates the heat exchanger temperature is above the switch setpoint; this switch is NOT resettable, and the heat exchanger must be replaced. If the Water Supply Hi-Limit Switch is open, it means the actual supply water temperature is above the switch setpoint; this switch will auto-reset once the temperature drops 10°F below the setpoint. If the Condensate Trap Pressure Switch is open, it suggests an undersized drain or partial/full trap blockage. If all safeties are closed and not receiving power, check the controller to s...

Summary

Installation & Operation Manual

IMPORTANT SAFETY INSTRUCTIONS

Crucial pre-installation and safety guidelines to be read and understood before installation.

WARNING: GAS LEAKS & INSTALLATION

Critical safety warnings regarding gas leaks and proper installation procedures.

YOUR SAFETY: READ BEFORE OPERATING

IF YOU SMELL GAS: EMERGENCY ACTIONS

Emergency procedures and safety steps to take if a gas leak is detected.

OPERATING INSTRUCTIONS

Step-by-step guide for starting the appliance safely and correctly.

CRITICAL SAFETY WARNINGS

HOT WATER SCALD HAZARDS

Risks associated with high water temperatures, especially for vulnerable individuals.

INSTALLATION & CODE REQUIREMENTS

Guidelines for qualified installers and compliance with local building codes.

GENERAL AND SAFETY INSTRUCTIONS

REGULATORY & INSTALLATION REQUIREMENTS

PRODUCT INFORMATION & SPECIFICATIONS

MASSACHUSETTS STATE REQUIREMENTS

CARBON MONOXIDE DETECTOR INSTALLATION

Mandated CO detector placement and type requirements specific to MA.

UNIT SPECIFICATIONS

INSTALLATION CLEARANCES

GENERAL VENTING GUIDELINES

VENTING TERMINATION OPTIONS

VENTING TERMINATION CLEARANCES

MANDATORY VENTING PRE-FIRE PROCEDURE

PRE-FIRE PROCEDURE STEPS

Step-by-step guide for preparing plastic venting systems before operation.

GAS LINE CONNECTION

GAS LINE INSTALLATION REQUIREMENTS

Codes, sizing, shut-off valves, and pressure testing for gas lines.

PLUMBING CONNECTIONS

WATER & HEATING SYSTEM CONNECTIONS

Guidelines for connecting potable water and heating circuits.

PLUMBING SETUP - BASE WATER HEATER

PLUMBING SETUP - DHW RE-CIRC VERSION

WATER SUPPLY QUALITY REQUIREMENTS

PURGING AIR FROM UNIT

CONTROL (LOW-VOLTAGE) WIRING

LOW-VOLTAGE WIRING DIAGRAM

Visual guide to connecting control and thermostat wires to the unit.

MAIN POWER (115 VAC) WIRING

FIELD WIRING REQUIREMENTS

Safety, codes, and conductor requirements for connecting main power.

115 VAC MAIN POWER WIRING

FAN-COIL INSTALLATION

CONTROL SETUP AND OPERATION

SETUP MENU OPERATIONS

ZONE SETUP CONFIGURATION

Configuration options for different zones and applications.

DHW SUPPLY TARGET ADJUSTMENT

Adjusting the hot water supply target temperature.

FAN COIL SETUP AND CONFIGURATION

DHW RECIRCULATION SETUP

BURNER AND COMMISSIONING PROCEDURES

BURNER SETUP AND OVERRIDES

Settings for burner operation, testing, and overrides.

COMMISSIONING EXERCISES

Procedures for initial startup, pump priming, and blower exercise.

COMMISSIONING CHECKLIST AND TESTS

WATER PRESSURE TESTING

Procedure for leak testing the plumbing system.

NO GAS SAFETY TEST

Verifying the safety shutdown when gas is absent.

TESTING GAS INLET PRESSURE

STATIC PRESSURE MEASUREMENT

Steps for measuring gas pressure when the unit is off.

GAS INLET PRESSURE TESTING (CONTINUED)

RUNNING PRESSURE MEASUREMENT

Steps for measuring gas pressure during operation.

TESTING COMBUSTION PERFORMANCE

COMBUSTION MEASUREMENT PROCEDURE

Steps for measuring CO2 and input rates for combustion analysis.

COMBUSTION ADJUSTMENT GUIDELINES

ADJUSTING GAS;AIR RATIO FOR COMBUSTION

How to adjust gas/air ratio for optimal combustion.

MAINTENANCE AND SERVICE SCHEDULE

ANNUAL BURNER CLEANING

Annual procedure for cleaning the burner assembly.

COMBUSTION CHAMBER AND CONDENSATE SYSTEM CARE

CLEANING COMBUSTION CHAMBER

Annual procedure for cleaning the combustion chamber.

TROUBLESHOOTING GUIDE

POTENTIAL FAULT CODES LIST

List of error codes and their descriptions for fault diagnosis.

TROUBLESHOOTING CORRECTIVE ACTIONS

FAULT CODE CORRECTIVE ACTIONS (ALM 4-6, NO FLOW)

Detailed steps to resolve specific fault codes like ALM 4-6 and no flow.

TROUBLESHOOTING CORRECTIVE ACTIONS (CONTD)

FAULT CODE CORRECTIVE ACTIONS (LOW PRES, NO FLAME)

Troubleshooting steps for low pressure and no flame fault codes.

APPENDIX A: INTERNAL WIRING DIAGRAM

APPENDIX B: SEQUENCE OF EVENTS