CE ONECLEAN
Graf UK Ltd
CE ONECLEAN
96,2%
98,6%
98,6%
Ammonia nitrogen 99,0%
Total nitrogen 79,1%
Nominal organic daily load (BOD5) 0,06 kg/d*PE
Nominal hydraulic daily flow (QN) 0,15 m3/d*PE
(water test)
(pit test)
2014
Treatment efficiency ratios
(at tested organis daily load BOD5=0,48
kg/d)
SS:
Watertightness
Treatment capacity (nominal designation)
Ntot:
passed
passed
Valid for one2clean plants build in Carat S underground tanks
DE - Handelspapier nach DIN EN 12566-3
EN 12566-3:2013-09
for treatment of domestic wastewater
Packaged domestic wastewater treatment plant
Otto Graf GmbH, Carl-Zeiss-Str. 2-6, Germany
SBR-treatment one2clean for 3-18 inhabitants
Material: Polypropylene (PP)
BOD5:
COD:
Effectiveness of treatment
Durability
Crushing resistance
passed
NH4-N:
Reaction to fire
Release of dangerous substances
Class E
NPD
Valid for one2clean plants build in Carat underground tanks