Troubleshooting
Machine does not turn on
1. Plug into working 110 AC outlet.
2. Check Sealer circuit breaker/fuse
Jaws do not close
1. Foot Switch malfunction.
2. Clogged air filter.
3. Safety System. Low Pressure set too high.
Jaws do not stay closed
1. Safety System, Low Pressure set to low.
No Vacuum
1. Air Supply. Unit requires 7.5 cfm @ 80 psi min.
2. Clogged Air Filter. Clean/Replace
3. Clogged nozzle. Clean/Replace
4. Clogged exhaust filter/Restricted exhaust. Check/Clean/Replace
5. Vacuum Timer set to low. Increase time
No Seal
1. Terminal screws loose. Tighten.
2. Heating Elements damaged/broken.
3. Seal Time set to low. Increase Time.
Poor Seal
1. Seal Timer set too low.
2. Seal Timer set too high.
3. One or both heating elements broken or damaged.
4. Teflon Covers dirty, burned or worn.
5. High Pressure setting too low. Readjust to 90
(80 minimum, 110 psi maximum!).