OIL FIRED LOBOY FURNACE -
85% + EFF
I
C
I
EN
C
Y
!
K
LR-100
K
LR-200
K
LF-100
KLF
-200
!
!
!
!
!
!
!
KLR-100 & 200 KLF-100 KLF-200
!
!
!
!
!
!
!
!
!
!
!
Please read the manual in its entirety before beginning installation. This
manual must be kept with the boiler for future reference. For maintenance
or question, please refer to your installer contractor directly.
!
18-06-2017 G2017-E1 Rev.I
Installation, Operation and
Service
Manual
INSTALLATIONS MUST MEET ALL LOCAL AND CODES THAT MAY
DIFFER FROM THIS
Question and Answer IconNeed help?

Do you have a question about the Granby KLR-200 and is the answer not in the manual?

Summary

Important Safety Advice for Furnace Operation

Product Information and Specifications

KLR-100 Furnace Dimensions

KLR-200 Furnace Dimensions

KLF-100 Furnace Dimensions

KLF-200 Furnace Dimensions

Furnace Installation Guide

Oil Tank and Piping Requirements

Details requirements for oil tank installation, piping systems (one-pipe and two-pipe), and code compliance.

Furnace Placement and Venting

Electrical Wiring Guidelines

Combustion and Ventilation Air

Appliance Installation in Large Spaces

Accessories Installation

Blocked Vent Switch (BVSO) Installation

Details the installation and function of the Blocked Vent Switch for Canadian installations.

Blocked Vent Switch Operation

Blocked Vent Switch Installation Procedure

Blocked Vent Switch Wiring

Blocked Vent Switch System Test

Air Conditioning Coil Installation

Humidifier Installation Guidelines

Burner Installation and Specifications

Burner Assembly and Installation

Provides steps for assembling and installing the furnace burner, including nozzle and electrode setup.

Setting Burner for Efficient Operation

Combustion Test Procedures

KLR Technical Information and Blower Data

KLF Technical Information and Blower Data

Furnace Operation and Settings

Blower Setting Adjustments

Details how to set the blower speed for optimal heating performance and air circulation.

Fan Timer Control Board (ST9103 A1028)

Explains the function and adjustment of the ST9103A1028 fan timer control board.

Comfort Adjustments for Furnace Operation

Off Cycle Air Circulation

Explains how to set blower for optional constant air circulation during furnace off cycles.

ST9103 A1028 Heating Sequence

Details the sequence of operations for heating calls initiated by the thermostat.

ST9103 A1028 Cooling Sequence

Details the sequence of operations for cooling calls initiated by the thermostat.

Servicing the Fan Timer ST9103 A1028

Service and Maintenance Procedures

Regular Maintenance Schedule

Details the recommended frequency and tasks for annual furnace maintenance.

Blower Removal Instructions

Provides step-by-step instructions and illustrations for removing the furnace blower assembly.

Changing the Furnace Nozzle

Air Filter Replacement

Electrical Wiring Diagrams

Heating and Cooling Wiring Diagrams (Beckett)

Genisys Control Schematic

Heating Only Wiring Diagrams

KLR-100 Exploded Parts View

KLR-100 Part List

KLR-200 Exploded Parts View

KLR-200 Part List

KLF-200 Exploded Parts View

KLF-200 Part List

Start-Up Test Results

Test Procedures

Granby KLR-200 Specifications

General IconGeneral
BrandGranby
ModelKLR-200
CategoryFurnace
LanguageEnglish