142
Basic Troubleshooting
Generator starts, but lacks electrical power
• Breaker switches may be off or tripped at generator.
Reset breaker if necessary.
• Breaker may be off or tripped inside power center.
Reset main breaker if necessary.
Generator makes clicking sound when trying to start
• Battery condition may be low. Recharge if necessary.
• Check for poor ground or battery connection.
INTERIOR LIGHTS
Lights icker
• Loose or defective bulb. Tighten or replace as needed.
• Converter is overheating. Open the cover to cool down
and reduce the load by turning off some 12-volt lights.
Lights dim or are half bright
• Low battery connection. Check battery condition and
recharge if necessary.
• Possible converter malfunction. Have converter
checked by an authorized service center.
• Possible loss of ground. Check for loose wire connec-
tion.
MICROWAVE
Will not operate
• Door open or timer OFF. Close door and turn timer
ON.
• No power to oven. Check power supply and circuit
breaker.
MONITOR PANEL
No lights on panel when switch is pressed
• Check battery voltage and condition.
• Check fuse at the battery; if fuse is good have a deal-
er or qualified RV technician check the condition of
panel.