24
EEPROM
chip
For 2436 model
Function description for the corresponding position
6
5
7
8
9
10
11
12
13
17
19
20
21
22
23
1
2
3
14
4
15
16
18
24
No. Content No. Content
1 Compressor iring terminal 13 Temp. controller connecting port
2 Reactor w iring terminal(connect a reactor betw een 2 and 3 ) 14 Function dial code SW4
3 Reactor w iring terminal(connect a reactor betw een 2 and 3 ) 15 Spot check button
4 Defrosting function dial codeSW5 16 Forced operation button
5 Pressure transducer port 17 Reserved
6 Air discharge temp.sensor port 18 Nixie tube display
7 Outdoor temp.sensor port(HP only) 19 Fan control port
8 Condenser temp.sensor port 20 Crankcase heating zone control terminal
9 Radiator temp.sensor port 21 Short w ire
10 High pressure sw itch port 22 Power supply connecting terminal
11 EXV drive port(HP only) 23 Power supply connecting terminal
12
Reversing valve
port 24 Indicator lamp
The photo is just for reference,actual unit will verify.
CUT OFF J2 JUMP FOR 24K MODEL.
THE FACTORY SETTING FOR 36K MODEL,