EasyManua.ls Logo

Grandstream Networks GDS371 Series - Page 41

Grandstream Networks GDS371 Series
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2” and dial out using the congured number in Number 2 if result matched, andcontinue to do such
checking and verication in loop till end.
Number [1-4] Called When Door Bell
Pressed
Congures SIP extension number (SIP Server mode), or IP address with port number (peering mode), to be
called when the Door Bell is pressed:
SIP Server mode:
The eld can be congured to store multiple one or multiple SIP extensions, if congured with multiple
extensions (ex: 1001, 1002, 1003), separated with “,the GDS3710 will ring one extension after the other in
aSerial Hunting Mode(GDS will ring each extension by default 15 seconds, this can be changed on the
Ring Timeout) or ring them simultaneously inParallel Hunting Mode.
When using UCM, users can also congure there a Ring Group extension (6400 for example) that will ring
multiple extensions simultaneously, or one by one depending on the Ring Group ring strategy.
If all phones are GXP21XX, the phone will stream the video frame by frame and users can open door either
by pressingRemote_PIN#or by pressing Open Door button if already congured.
If early medial is enabled on phone side, user can send the PIN code using the Open-Door button before
answering the call (Of course users can open the door also after answering the call).
Peering mode:
Usershould congure multiple IP addresses of phones instead of SIP extensions, when Door Bell pressed
the GDS3710 will ring the congured IP Addresses inSerial or Parallel Modeaccording to Doorbell Call
Mode strategy.
If early media is enabled, the GXV33XX will receive the video stream while it is ringing, and user can open
door by pressing the Open-Door button if already congured (Of course users can open the door also after
answering the call).
GXP21XX phones receive the GDS3710 video using JPEG streaming this means that it will receive video if
early media is enabled or disabled.Note:This eld supports a Maximum of 256 characters.
Maximum Number of Dialed Digits
Congure the maximum digits allowed to dial in the keypad. Once the congured condition is satised, the
device will send out the number to call automatically without pressing #. It is disabled if set to 0.
Note: Conguration can be done only on the GDS3710.
No Key Input Timeout(s)
Denes the timeout (in seconds) for no key entry. If no key is pressed after the timeout, the digits will be sent
out without pressing #. The default value is 4 seconds. The valid range is from 1 to 15.
Note: Conguration can be done only on the GDS3710.
Press Doorbell Schedule
Congure a schedule for the Doorbell button, once congured, the doorbell with turn ON/OFF based on
congured schedule. Default setting is All Day”.
Remote PIN to Open the Door
Congures PIN code stored in the GDS3710, remote SIP phone needs to input and match this PIN (the PIN is
sent via DTMF while in call) so that the GDS3710 can open the door.
Note:For enhanced security, when the call is initiated from GDS then only the numbers existing in “White List”
will be able to use DTMF PIN to open door remotely.
Local PIN Type Three options are available: Private Card PIN, Unied PIN or Card and Private PIN.
Private PIN: Means every member has a private PIN, the GDS will record who unlocked the door every time.
Users need to enter the following sequence from the GDS3710 to open the door
[*Virtual Number*Private
PIN#]
.
Notes:
1. When Local PIN type is set toprivate PIN, users can also open the door by swiping their cards.
2. If “Disable Keypad SIP Number Dialing” is checked, users will be able to open door using private PIN with
following sequence[Private PIN].
Note:
Door can still be opened byCardand with the sequence [*Virtual Number*Private PIN].
For more details and conditions, refer to[Disable Keypad SIP Number Dialing].
Unied PIN: Means all members share a same PIN to unlock the door. Users need to enter the following
sequencefrom the GDS3710 keypad to open the door
[*Local PIN to Open the Door#]
.