Home
Grant
Heat Pump
Aerona3 HPID10R32
Grant Aerona3 HPID10R32 User Manual
4
of 1
of 1 rating
88 pages
Give review
Manual
Specs
To Next Page
To Next Page
Loading...
Grant
Aer
ona³
Air to W
ater H
igh Ef
ficienc
y
Hea
t Pump R
ange
Installation and
Ser
vicing Instr
uct
ions
R
32
IRL| DOC 00
17
| REV
00.00|
FEBRUARY
20
21
2
Table of Contents
Default Chapter
3
Table of Contents
3
1 Introduction
4
General
4
Main Components
4
Planning Permission
4
Important Advice
4
Product Contents
4
Installation Accessories
4
Control Parameters
4
Heat Pump Components
4
2 Technical Data
6
Heat Pump Technical Data
6
Main Supply Cable
6
Base Tray Heater
6
Heat Pump Dimensions
7
Remote Controller Dimensions
8
3 Installation Information
9
Introduction
9
Heating System Design Criteria
9
Regulations
10
Heat Pump Location
10
Preparation for Installation
10
Installing the Heat Pump
11
Metering for Domestic RHI Installations
12
Volumiser Tanks
12
Hydraulic Diagram
13
Before You Commission
14
Completion
15
Installation Checklist
16
4 Sealed Systems
18
Sealed System Requirements
18
Filling the Sealed System
19
Pressure Relief (Safety) Valve Operation
19
5 Domestic Hot Water
20
Temperature Control
20
Heat Pump Cylinders
20
Legionella
21
Automatic DHW Boost Kit
21
6 Electrical
24
Main PCP
24
Terminal PCB Input/Output
25
Power Supply
25
Wiring First Fix Options
26
Tightening Torques
27
Solar Thermal
27
Connection of Heating System Control
27
Connection of Display Pad
27
First Fix Wiring Options
29
Second Fix Wiring
30
7 Display Pad
32
Installation Requirements
32
Installing the Display Pad
32
Connecting the Display Pad
33
Buttons
34
Display Panel
35
Appendix C - Parameters 82
36
Heat Pump Operation
36
Weather Compensation
38
Water Pump Management
39
Frost Protection
42
ON/OFF DHW Production Remote Contact
44
ON/OFF Heating Remote Contact
45
Night Mode
46
Low Tariff
47
8 Operation
36
9 Commissioning
48
System Setup
48
Setting the Day and Time
48
Access for Parameter Settings
49
Accessing the Parameter Setting Menu
49
(Installer Level)
49
Temperature Control - DHW Function
49
Parameters Input/Output
50
Remote Controller Back Light Display
50
Parameters
50
Weather Compensation
51
Frost Protection Function Setting
51
Pump Operation and Air Bleeding from Heating System
51
Pump Output Setting
51
Coastal Installations
51
10 Servicing
52
General
52
Air Inlet and Outlet
52
Condensate Disposal
52
Heating System Connections
52
Heat Pump Controls
52
Refrigerant
52
Monitor Display Function
53
11 Fault Finding
54
Error Code Display
54
Error History Display
54
Reset Error Code Display
54
Error Codes
55
Table of Controller PCB and Terminal PCB Alarms
58
Error Codes and PCB Alarm Figures and Tables
59
12 Spare Parts
62
Exploded Diagram - HPID6R32
62
Spare Parts List - HPID6R32
63
Exploded Diagram - HPID10R32
64
Spare Parts List - HPID10R32
65
Exploded Diagram - HPID13R32
66
Spare Parts List - HPID13R32
67
Exploded Diagram - HPID17R32
68
Spare Parts List - HPID17R32
69
13 Declaration of Conformity
70
16 Product Fiches
70
14 Health and Safety Information
71
General
71
Refrigerant (R32)
71
15 Disposal and Recycling
71
17 Guarantee
76
Appendix A Parameters List
82
Appendix B Wiring Diagrams
84
Appendix C - Parameters Record
86
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Grant Aerona3 HPID10R32 and is the answer not in the manual?
Ask a question
Grant Aerona3 HPID10R32 Specifications
General
Model
Aerona3 HPID10R32
Type
Air Source Heat Pump
Heating Capacity
10 kW
Refrigerant
R32
Energy Efficiency Rating
A+++
Related product manuals
Grant Aerona3 Series
88 pages
Grant Aerona HPAW65
48 pages
Grant QR Range
44 pages