15. SPECIFICATION
Battery:
Charge current / Power 120mA -1A / max. 38W with power cord 110-240VAC
Outputs:
Output 1:
Charge current approx. 1A pulsed with delta peak cut-off
NiCd & NiMH- Batteries:
Cell count 4 - 10 cells
Capacity 0.25 Ah … 7 Ah
Output 2:
Charge current 0.5A pulsed with delta peak detection
NiCd & NiMH- Batteries:
Cell count 4 - 10 Zellen
Capacity 0.25 Ah … 7 Ah
Output 3:
Charge current approx. 0.5A pulsed with delta peak cut-off
NiCd & NiMH- Batteries:
Cell count 1 - 4 cells
Capacity 0.25 Ah … 7 Ah
Outputs 4 & 5:
Charge current approx. 0.25A pulsed
NiCd & NiMH- Batteries:
Cell count 1 - 10 cells
Capacity 0.25 Ah … 7 Ah
Lead-acid / lead-gel batteries:
Cell count 1-6
Battery Voltage 2, 4, 6, 8, 10, 12V
Capacity 0.5-20 Ah
Outputs 6 & 7:
Charge current approx. 0.12A pulsed
NiCd & NiMH- Batteries:
Cell count 1 - 10 cells
Capacity 0.25 Ah … 7 Ah
Lead-acid / lead-gel batteries:
Cell count 1-6
Battery voltage 2, 4, 6, 8, 10, 12V
Capacity 0.5-20 Ah
General:
Operating voltage range AC input: 110-240V AC 50/60Hz
Weight approx. 530g
Dimensions approx. (W x D x H) 142 mm x 130 mm x 84 mm
The stated values are guidelines, and may vary according to battery state, temperature etc.