EasyManua.ls Logo

GRE swim & fun HPGIC30 - User Manual

GRE swim & fun HPGIC30
160 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
H0846600_REVA
* Original instrucons, Instrucons d’origine, Instrucciones originales, Original anleitung, Instruzioni originali, Instruçôes originais, Originele
instruces, Oryginalne instrukcje, Originální návod, Originalinstrukoner, Pôvodný návod, originale instrukoner, alkuperäiset ohjeet,
Originalanvisning
Ø18
(x2)
(x2)
EN
Quick Start Guide*
FR
Guide de Démarage Rapide
ES
Guia de Início Rápido
DE
Kurz- oder Schnellstartanleitung
IT
Guida Rapida
PT
Guia Rápido
NL
Snelstartgids
PL
Przewodnik Szybkiego Uruchamiania
CS
Stručný návod
SV
Snabbstartsguide
SK
Príručka pre rýchle spustene
DA
Hurtig startvejledning
FI
Pikakäynnistysopas
NO
Hurtigstartsveildning
www.grepool.com
www.swim-fun.com
HPGIC30, HPGIC45,
HPGIC60, HPGIC75
Heatpump - 7, 9, 12, & 14

Table of Contents

Other manuals for GRE swim & fun HPGIC30

Questions and Answers

  • S
    Sara HendersonAug 17, 2025
    Why is my GRE swim & fun HPGIC30 Heat Pump working but the water temperature not increasing?
    • M
      Mark BartlettAug 18, 2025
      If your GRE Heat Pump is working but the water temperature isn't increasing, several factors could be at play. First, ensure the operating mode is set to 'BOOST' and manually set the filtration to 24/24 until the temperature rises. Check that the automatic filling valve isn't stuck in the open position, as this can continuously introduce cold water. Consider installing a heat-insulated cover to minimize heat loss. A dirty evaporator can also hinder performance, so clean it. Finally, verify that the heat pump is appropriately sized for your pool and its environment.
  • C
    Crystal RobinsonAug 20, 2025
    What to do if my GRE Heat Pump trips the circuit breaker?
    • A
      Andrew SchaeferAug 20, 2025
      If your GRE Heat Pump trips the circuit breaker, it could be due to a couple of reasons. First, check that the circuit breaker is correctly sized and that the cable section used is appropriate. If the supply voltage is too low, you should contact your electricity supplier.
  • M
    Mrs. Linda WrightAug 22, 2025
    Why does the fan run, but the compressor stops on my GRE swim & fun HPGIC30 Heat Pump?
    • A
      allenmichaelAug 22, 2025
      If your GRE Heat Pump's fan is running but the compressor stops intermittently without an error message, it could be due to low outdoor temperatures, which cause the appliance to perform defrost cycles. Alternatively, the evaporator might be clogged with dirt. Clean the evaporator to restore its performance.
  • B
    Brittany PrestonAug 26, 2025
    What to do if my GRE swim & fun HPGIC30 is not working?
    • F
      Felicia AdamsAug 26, 2025
      If your GRE Heat Pump isn't working, start by checking the supply voltage and the F1 fuse. Also, ensure that water is circulating correctly within the appliance. A zero or insufficient water flow rate can also prevent the appliance from functioning; verify proper water circulation.
  • C
    Craig CooperAug 27, 2025
    What to do if my GRE Heat Pump is discharging water?
    • J
      jaimehamiltonAug 28, 2025
      If your GRE Heat Pump is discharging water, it indicates a water leak within the appliance. Shut down the appliance and run the filter pump to circulate water. If water continues to flow through the condensate drainage lines, contact your retailer.
  • J
    Jack PalmerAug 30, 2025
    Why is the evaporator iced over on my GRE swim & fun HPGIC30?
    • J
      Jane McdonaldAug 30, 2025
      If your GRE Heat Pump's evaporator is iced over, it could be due to a low outdoor temperature (below -7°C). In this case, the appliance will soon switch to its defrost cycle to melt the ice. If the appliance cannot defrost its evaporator, it will stop itself.
  • K
    Kimberly LongSep 1, 2025
    Why doesn't my GRE swim & fun HPGIC30 Heat Pump start heating immediately?
    • A
      Amber FlynnSep 2, 2025
      If your GRE Heat Pump does not start heating straight away, ensure that the water is circulating correctly in the appliance and that the hydraulic connections are correct. Also, verify that the water flow rate is sufficient. The appliance will stop when the outdoor temperature falls below -7 °C.
  • K
    Karen GrahamSep 4, 2025
    What to do if my GRE swim & fun HPGIC30 is smoking?
    • R
      Raymond BurtonSep 4, 2025
      If your GRE Heat Pump is 'smoking,' immediately switch off and disconnect the appliance and contact your retailer, as this is not normal operation.
  • A
    astarkSep 6, 2025
    Why does my GRE Heat Pump trip the circuit breaker?
    • R
      Rachael SolisSep 6, 2025
      If your appliance is tripping the circuit breaker, verify that the circuit breaker is correctly dimensioned and that the cable section used is correct. The supply voltage may also be too low, in which case you should contact your electricity supplier.
  • K
    Kara ElliottSep 9, 2025
    Why is my GRE swim & fun HPGIC30 'smoking'?
    • A
      Angela RiddleSep 9, 2025
      The appliance may appear to be 'smoking' when it is in a defrost cycle, during which water is converted to gas. However, if the appliance is not in its defrost cycle, this is not normal. Turn off and disconnect the appliance immediately.

GRE swim & fun HPGIC30 Specifications

General IconGeneral
TypeHeat Pump
Suitable for pool volumeup to 30 m³
COP6.4 - 12.5
Power supply220-240V/50Hz
Minimum water flow2 m³/h
Max Water Temperature40°C