Concealed Ceiling Type FCU

Questions and Answers

  • S
    Sherry SimmonsAug 9, 2025
    What to do if my Gree Air Conditioner is not running?
    • W
      William FergusonAug 9, 2025
      If your Gree Air Conditioner isn't running, there could be several reasons: * Check if there is a power supply. If not, repower the unit. * Ensure the power plug is tightened. * The motor might be burnt out, in which case you should replace the motor and check the wiring.
  • E
    Edward StoneAug 15, 2025
    How to fix a Gree FP-136WAH/GHL-K that leaks water?
    • T
      Tara KingAug 15, 2025
      If your Gree Air Conditioner is leaking water, here are some potential causes and solutions: * The condensate pipe might be clogged; clean the drain pipe. * The unit may not be installed correctly; adjust the unit to maintain a certain inclination degree. * High environmental air humidity can cause leaks; implement dehumidification measures. * If the fan stops but cold water is supplied continuously, close the water dampers or run the unit. * A loose discharge valve can also cause leaks; tighten the valve.
  • M
    murrayjamesAug 20, 2025
    Why is my Gree FP-136WAH/GHL-K Air Conditioner making abnormal noise?
    • C
      Christopher WardAug 21, 2025
      Abnormal noise from your Gree Air Conditioner can stem from several issues: * Deformed volute or blade, or contact between the volute and blade. Replace the volute or the blade. * A clogged air filter. Clean the filter. * Foreign matter at the inlet/outlet or inside the duct. Remove any obstructions. * Abnormal noise from the motor. Replace the motor. * Loose fastening screws. Tighten them.
  • M
    Marvin WrightAug 27, 2025
    What to do if my Gree FP-136WAH/GHL-K cooling or heating effect is poor?
    • D
      Dale SimmonsAug 27, 2025
      If your Gree Air Conditioner isn't cooling or heating effectively, consider these possibilities: * The air filter may be clogged, so clean it. * The dampers might not be open, so open them. * The fins could be clogged or damaged, requiring cleaning or repair. * The entering water temperature may be too high or too low for effective cooling; adjust it accordingly.
  • P
    patrickwilliamsSep 1, 2025
    Why is my Gree FP-136WAH/GHL-K airflow rate too low?
    • A
      Alison Mason DDSSep 1, 2025
      A low airflow rate in your Gree Air Conditioner can be due to: * A clogged air filter. Clean the air filter. * Foreign matter at the return. Clear any obstructions. * Excessive duct resistance. Lower the duct resistance or reselect the unit.

Summary

Product Introduction

Product Lineup and Specifications

Detailed list of FCU models with cooling/heating capacities and power supply.

FCU Product Features

Key characteristics and benefits of the FCU units, including fan design and construction.

Technical Data

FCU Technical Data Overview

Comprehensive technical specifications for FCU units.

FCU Data at Nominal Conditions

Performance specifications under standard operating conditions.

Design and Selection

FCU Selection Principles

Guidelines for selecting the appropriate FCU model based on load and environment.

FCU Selection Steps

Step-by-step process for choosing the correct FCU unit for a given application.

FCU Selection Example

Practical example demonstrating the FCU selection process.

Unit Installation

Test Operation, Troubleshooting & Maintenance

FCU Error List and Troubleshooting

Common FCU problems, their causes, and corrective measures.

FCU Electric Diagrams

Wiring schematics for FCU units, essential for electrical connections.