EasyManua.ls Logo

Gree G17-135PACSW - User Manual

Gree G17-135PACSW
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Please read the entire manual carefully to
ensure proper operation of the product.
To find an electronic version of this manual,
please visit www.greeproducts.com
Phone: 1-866-658-0466
Email: customerservice@greeproducts.com
G17-12PACSW
G17-12PACSH
G17-135PACSW With Heat Pump
Portable Room
Air Conditioner
Owners
Manual
Write the model and serial numbers below for your records:
Model #
Serial #
Date Purchased
Question and Answer IconNeed help?

Do you have a question about the Gree G17-135PACSW and is the answer not in the manual?

Summary

Safety Information

Electrical Information

Details electrical safety precautions and the function of the current detection device in the power cord.

Installation Instructions

Before You Begin

Crucial safety guidelines and preparation steps before starting the installation process.

Where to Install the Unit

Guidance on selecting the optimal and safe location for unit placement.

Vertical Double Hung Window

Detailed steps for installing the unit's window kit in a vertical double hung window.

Horizontal Sliding Window

Detailed steps for installing the unit's window kit in a horizontal sliding window.

Operating Instructions

Before You Call

Troubleshooting Guide

A list of common problems and their step-by-step solutions.

Malfunction Code

Explanation of error codes displayed by the unit and their troubleshooting.

Summary

Safety Information

Electrical Information

Details electrical safety precautions and the function of the current detection device in the power cord.

Installation Instructions

Before You Begin

Crucial safety guidelines and preparation steps before starting the installation process.

Where to Install the Unit

Guidance on selecting the optimal and safe location for unit placement.

Vertical Double Hung Window

Detailed steps for installing the unit's window kit in a vertical double hung window.

Horizontal Sliding Window

Detailed steps for installing the unit's window kit in a horizontal sliding window.

Operating Instructions

Before You Call

Troubleshooting Guide

A list of common problems and their step-by-step solutions.

Malfunction Code

Explanation of error codes displayed by the unit and their troubleshooting.

Overview

This document is an owner's manual for a portable room air conditioner, specifically models G17-12PACSW, G17-12PACSH, and G17-135PACSW with Heat Pump. It provides comprehensive instructions for installation, operation, and maintenance of the unit, emphasizing safety and proper usage.

Function Description

The portable room air conditioner is designed to provide cooling and, for the G17-135PACSW model, heating to an indoor space. It utilizes a refrigerant system to remove heat and moisture from the air, discharging hot air through an exhaust hose. The unit features a programmable digital thermostat for precise comfort control, allowing users to select a desired temperature within a range of 61°F (16.1°C) to 86°F (30°C) in COOL or HEAT mode. It also includes a 24-hour programmable clock timer, enabling users to set specific times for the unit to turn on or off. The unit is equipped with casters for easy mobility and is intended for indoor use only.

Usage Features

The air conditioner offers multiple operating modes: COOL, DRY, FAN, and HEAT (for models with a heat pump).

  • COOL Mode: Provides cooling to the room. The temperature setting range is 61°F (16.1°C) to 86°F (30°C).
  • DRY Mode (Evaporative Dehumidifier): This mode removes moisture from the air. The unit's evaporative technology drips condensed water onto the condenser, which then evaporates the water and expels it with hot air through the exhaust hose. If water is not fully evaporated, it collects in a pan and is pumped back up for evaporation. The fan speed button is inactive in DRY mode.
  • FAN Mode: Circulates air without cooling or heating.
  • HEAT Mode (G17-135PACSW only): Provides heating to the room. The temperature setting range is 61°F (16.1°C) to 86°F (30°C).

The unit features a 3-speed fan (Low, Med, High) and an Auto Fan setting. In Auto Fan mode, the fan speed automatically adjusts based on the current room temperature and the thermostat setting to optimize comfort.

A Sleep Mode is available for enhanced comfort and energy conservation. When activated in COOL mode, the preset temperature automatically increases by 2°F after the first hour and another 2°F after the second hour. This mode limits compressor usage and is not available in FAN or DRY modes.

The unit is controlled via a control display on the unit itself and an LCD remote control. The remote control displays all settings and includes an X-Fan Button. When pressed in COOL or DRY mode, the X-Fan icon appears, and the interior fan continues to operate for a few minutes after the compressor turns off to disperse excess condensation, helping to prevent mold and mildew growth. This feature is not available in AUTO or FAN modes.

A Child Lock Function can be activated by simultaneously pressing the “+” and “-” buttons on the remote control when it is turned off. When active, an icon is displayed on the remote, and it will not send signals to the unit.

The unit also has a Loss of Power Protection with Auto Restart feature. In the event of a power interruption, the unit remembers its previous settings (mode, temperature, and fan speed) and automatically resumes operation with those settings once power is restored.

For continuous drainage, the unit offers options from both the bottom and middle holes. The bottom hole option is for continuous drainage when the chassis is full, indicated by a buzzer sound and "H8" display. The middle hole option allows water to automatically empty into a floor drain by attaching a garden hose (not included).

Maintenance Features

Regular maintenance is crucial for the optimal performance and longevity of the air conditioner.

  • Filter Cleaning: The air filters should be cleaned once every three weeks, or more frequently if the operating environment is dusty. To clean, remove the filter(s), use cleaner or warm water, and then dry them in a shady place. Do not use a hair dryer to dry the filters. The unit should not be operated without the filters installed.
  • Outer Case Cleaning: The outer case can be cleaned with a soft towel to wipe off dust. For dirtier surfaces, a mild detergent can be used. The grill should be cleaned with a cleaner or soft brush.
  • Collected Water Removal: The manual details procedures for removing collected water from the chassis. For the continuous drainage lower hole option, if the chassis becomes full (indicated by "H8" and a buzzer), the unit needs to be moved to a level surface, and the rubber plug in the drainage pipe should be removed to discharge the water. After draining, the plug and pipe should be reinstalled. For the continuous drainage middle hole option, a drain connector (included) can be screwed onto the spout, and a garden hose can be inserted into the connector to direct water to a floor drain. It is important to ensure the portable unit is on a level surface and the hose is clear of obstructions and directed downward to prevent water from filling the chassis and causing the unit to shut off.
  • Remote Control Battery Replacement: The remote control uses two AAA 1.5V dry batteries. To replace them, press the back side of the remote marked "OPEN," slide out the battery cover, replace the batteries ensuring correct polarity, and then reinstall the battery cover. It is recommended to remove batteries if the remote control will not be used for extended periods.

The manual also provides troubleshooting information for common issues and malfunction codes, advising users to contact customer service if solutions fail. Safety warnings are highlighted throughout, emphasizing the importance of disconnecting power before cleaning, avoiding harsh cleansers, and handling the unit carefully to prevent injury from sharp edges or fins.

Gree G17-135PACSW Specifications

General IconGeneral
TypeSplit Air Conditioner
RefrigerantR410A
Compressor TypeRotary
ModelG17-135PACSW
Cooling Capacity13500 BTU/h
Power Supply50Hz

Related product manuals