EasyManuals Logo

Gree GEH09AA-K3DNA1D WIFI User Manual

Gree GEH09AA-K3DNA1D WIFI
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
4
Technical Information
Service Manual
2.2 Operation Characteristic Curve
2.3 Capacity Variation Ratio According to Temperature
Cooling Heating
0
09070605040302010
1
10
210010908070605040302010
80
11
10
9
8
7
6
5
4
3
2
1
0
11
10
9
8
7
6
5
4
3
2
1
0
• Conditions
Indoor : DB27˚C/WB19˚C
Outdoor : DB35˚C/WB24˚C
Indoor air flow : High
Pipe length : 5m
• Conditions
Indoor : DB20˚C/WB15˚C
Outdoor: DB7˚C/WB6˚C
Indoor air flow : High
Pipe length : 5m
220V
230V
240V
220V
230V
240V
Current (A)
Current (A)
Compressor frequency(Hz)
Compressor frequency(Hz)
Cooling Heating
32 33 34 35 36 37 38 39 43 –15 –10 –5 05
710
40 41 42
100
105
95
90
85
80
75
70
65
60
55
50
Outdoor temp. (˚C)
110
100
90
80
70
60
50
40
Outdoor temp. (˚C)
Capacity ratio (%)
Capacity ratio (%)
• Conditions
Indoor: DB27°C/WB19°C
Outdoor: DB35°C/WB24°C
Indoor air flow: High
Pipe length: 5m
• Conditions
Indoor: DB20°C/WB15°C
Outdoor: DB7°C/WB6°C
Indoor air flow: High
Pipe length: 5m