INSTALLATION INSTRUCTIONS
32
Additional refrigerant charging amount for R32.
Diameter of connection pipe mm
Liquid pipe Gas pipe
Ф6
Ф6 or Ф9.5
Ф9.5 or Ф12
Ф12
Ф16
Ф19
Ф22.2
Ф16 or Ф19
Ф19 or Ф22.2
Ф25.4 or Ф31.8
_
_
Cooling only,
cooling and heating
(g / m) (g / m)
Cooling only
(g / m)
cooling and
heating
16
40
80
136
200 200
280280
48
24
12
12
200
280
96
96
40
16
Indoor unit throttle Outdoor unit throttle
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.