Super Free Match 
 Service Manual 
 
    PRODUCT 
9 
Model GWH(18)TC-K3DNA1E/I GWH(28)TD-K3DNA1C/I
Cooling kW  5.3  8.4 
Capacity 
Heating kW  5.6  8.6 
Power supply  V-Ph-Hz  220~240-1-50  220~240-1-50 
Motor power input  kW  0.045  0.1 
m3/h 950  1200 
Air flow volume 
CFM 559  706 
Sound pressure level 
(SH/H/MH/M/ML/L/SL) 
dB(A) 49/44/41/39/36/33/30 52/50/48/45/42/39/35 
Output kW  0.025  0.07 
Fan motor 
Running current  A  0.1  0.24 
Gas inch 5/8″(Φ15.9mm) 5/8″(Φ15.9mm) 
Liquid inch  1/4″(Φ6.35mm) 1/4″(Φ6.35mm) 
Connecting pipe 
Connection method  Flare Connection  Flare Connection 
External dia.  mm  Φ20  Φ20 
Drain pipe 
Thickness mm  1.5  1.5 
Outline dimension  W×D×H  mm  1018×230×319  1178×264×326 
Package dimension  W×D×H  mm  1097×397×340  1256×414×364 
Net Weight/Gross weight  kg  15.0/18.5  17.0/23.0 
20'GP 174  138 
40' GP  366  303 
Loading quantity 
40' HQ  427  349 
 
Notes: 
a. The rated cooling capacity data is measured under the following work condition: Indoor Temperature is 27℃
DB, 19℃WB. Outdoor Temperature is 35℃DB. The rated heating capacity data is measured under the following 
work condition: Indoor Temperature is 20℃DB. Outdoor Temperature is 7℃DB, 6℃WB. 
b. The data will change with the change of products. Refer to those parameters listed on nameplate. 
c. Noise was tested in semi-silenced room, so the actual noise value will be a little higher for change of ambient.