What to do if my Gree GFH60K3FI has a malfunction of drive module sensor?
- CChad GriffinSep 23, 2025
If there is a malfunction of the drive module sensor in your Gree Air Conditioner, please turn off the unit and ask a professional for maintenance.
What to do if my Gree GFH60K3FI has a malfunction of drive module sensor?
If there is a malfunction of the drive module sensor in your Gree Air Conditioner, please turn off the unit and ask a professional for maintenance.
How to fix a Gree GFH60K3FI that will not start?
If your Gree Air Conditioner won't start, check the power supply connection first. Then, inspect for electrical leakage that might be tripping the leakage switch and reset it. Ensure the operating keys are unlocked, and check the control loop functionality.
Why is my Gree GFH60K3FI not heating properly?
If your Gree Air Conditioner isn't heating well, begin by cleaning or replacing the air filter. Ensure all doors and windows are firmly closed and increase the set room temperature. Inspect for refrigerant leakage and verify that the outdoor ambient temperature is not lower than -5°C. Also, examine the control loop for any issues.
What to do if my Gree Air Conditioner operates for a while and then stops?
If your Gree Air Conditioner stops after running for a bit, first check for any obstacles blocking the condenser and remove them. Next, examine the control loop for any abnormalities. Also, if you're using cooling operation, ensure the outdoor temperature isn't above 48°C.
What to do if my Gree GFH60K3FI Air Conditioner has a malfunction of drive current?
If there is a malfunction of drive current in your Gree Air Conditioner, please turn off the unit and ask a professional for maintenance.
What to do if my Gree Air Conditioner has a malfunction of the condenser temperature sensor?
If your Gree Air Conditioner is showing a malfunction of the condenser temperature sensor, please turn off the unit and ask a professional for maintenance.
What to do if my Gree Air Conditioner has a malfunction of the indoor ambient temperature sensor?
If there is a malfunction of the indoor ambient temperature sensor in your Gree Air Conditioner, please turn off the unit and ask a professional for maintenance.
What to do if my Gree GFH60K3FI Air Conditioner has a malfunction of the evaporator temperature sensor?
If your Gree Air Conditioner is showing a malfunction of the evaporator temperature sensor, please turn off the unit and ask a professional for maintenance.
What should I do if my Gree GFH60K3FI has freeze protection?
If your Gree Air Conditioner is under freeze protection, please turn off the unit and ask a professional for maintenance.
What should I do if my Gree GFH60K3FI has compressor phase protection?
If your Gree Air Conditioner indicates compressor phase protection, please turn off the unit and ask a professional for maintenance.
Detailed steps for installing the indoor unit, including dimensions and mounting.
Procedures and considerations for installing the outdoor unit, including dimensions and mounting.
Instructions for processing, bending, and connecting the refrigerant pipes.
Steps for performing vacuum and checking for gas leaks after installation.
Instructions for performing electrical wiring between indoor and outdoor units.
Detailed steps for installing the indoor unit, including dimensions and mounting.
Procedures and considerations for installing the outdoor unit, including dimensions and mounting.
Instructions for processing, bending, and connecting the refrigerant pipes.
Steps for performing vacuum and checking for gas leaks after installation.
Instructions for performing electrical wiring between indoor and outdoor units.
| Cooling Capacity | 6.15 kW |
|---|---|
| Heating Capacity | 6.45 kW |
| Power Supply | 220-240V/50Hz/1Ph |
| Refrigerant | R32 |
| Compressor Type | Rotary |
| Indoor Unit Dimensions (W x H x D) | 970 x 300 x 224 mm |
| Outdoor Unit Dimensions (W x H x D) | 802 x 555 x 350 mm |