Service Manual
Installation and Maintenance
40
Unsolder each connection pipe
(Note:discharge the refrigerant
completely before unsoldering).
Remove the screws xing condenser
and then remove the condenser.
ProcedureStep
7. Remove evaporator
8. Remove condenser
Unsolder each connection pipe
(Note:discharge the refrigerant
completely before unsoldering).
Remove the screws xing evaporator
and then remove the evaporator.
9. Remove axial ow blade
Remove the nuts of axial ow blade;
remove the washer and then remove
the axial ow blade.
Nut