U-Match Series Service Manual 
21 
3.2 Operation View   
3.2.1 Silk Screen of Buttons 
 
Figure 2-3-3 Silk screen of buttons 
3.3.2 Instruction to Function of Buttons 
Table 2-3-2 Instruction to buttons of wired controller 
 Function selection and canceling; 
 Press it for  5s  to  view  the  ambient temperature; press Mode button to 
select  viewing  outdoor  ambient  temperature  or  indoor  ambient 
temperature. 
 Running temperature setting range of indoor unit: 16-30
℃
; 
 Timer setting range: 0.5-24hr; 
 Setting of air function level; 
 Setting of energy-saving temperature; 
 Setting of cleaning class. 
Setting of high/medium high/medium/medium low/low/auto fan speed. 
Setting of auto/cooling/heating/fan/dry mode of indoor unit. 
Switch  over  among  these  functions  of  swing/air/sleep/health/ 
I-Demand/out/turbo/save/e-heater/X-fan/clean/quiet. 
Press Mode and ▲ buttons at the same time for 5s under off state of the unit 
to enter/cancel memory function (If memory function is  set, indoor unit will 
resume original setting state after power failure and then power recovery. If 
not, indoor unit is defaulted to be off after power recovery. Ex-factory setting 
of memory function is on). 
Upon startup of  the  unit  without  malfunction or under off state of  the  unit, 
press  ▲  and ▼ buttons  at  the same time  for  5s to enter  lock  state.  In  this 
case,  any  other  buttons  won‟t  respond  when  pressing.  Repress  ▲  and  ▼ 
buttons for 5s to quit lock state. 
Enquiry and 
setting of address 
of wired controller 
Under off state of the unit, press Mode and Function buttons at the same time 
for 5s to set the address. (More details please refer to project debugging) 
Setting of project 
parameters (More 
details please 
refer to the Notes) 
Under off state of the unit, press Function and Timer buttons at the same time 
for 5s to go to the debugging menu. Press Mode button to adjust the setting 
items and press ▲ or ▼ buttons to set the actual value. 
Switch between 
Fahrenheit and 
Centigrade 
Under off state of the unit, press Mode and ▼ buttons at the same time for 5s 
to switch between Fahrenheit and Centigrade. 
Viewing historical 
malfunction 
Continuously  press  Function  and  ▼  buttons  for  5s  to  view  historical 
malfunction. Then press ▲ and ▼ buttons to adjust displayed contents. The 
timer  displaying  position  displays  the  sequence  of  malfunction  and  the 
detailed error code. The 5
th
 displayed malfunction is the last malfunction.