U-Match Series DC Inverter Service Manual
131
3. Remove gas liquid
separator
1. Discharge the refrigerant
inside the pipeline and
recycle the refrigerant during
discharging;
2. Unsolder the 4-way valve
assy from gas liquid
separator;
3. Remove the gas liquid
separator.
4. Remove compressor
1. Discharge the refrigerant
inside the pipeline and
recycle the refrigerant during
discharging;
2. Unsolder the 4-way valve
assy from compressor;
3. Remove the nut fixing
compressor;
4. Take away the compressor
from chassis.
5. Assemble unit
Assemble the unit in the
reverse procedures of
disassembly.
42k/48k/60k
Disassembly and Assembly of external casing
Remark :
Step
Illustration
Handling Instruction
1. Remove external
casing
1. Remove the top cover and
handle;
2. Remove the grille, outer
case and right side plate.