EasyManua.ls Logo

Gree GKH42K3FI

Gree GKH42K3FI
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
U-Match Series DC Inverter Service Manual
135
2. Disassembly of
water-containing plate
Disassemble the fastening
screws on the
water-containing plate, pull
upward and remove the
water-containing plate.
Disassembled
water-containing plate is
shown in the graph.
Disassembly of fan and motor
Remark: Make sure that the power supply is cut off before disassembling and protect all the parts during
disassembly.
Step
Illustration
Handling Instruction
Disassembly of fan
motor
Disassemble the fixing
screws on the fan
components. (As is shown in
Graph 10, circle represents 6
screws.)
Disassemble the fastening
screws on the fan and motor.
Remove the fan. (As is
shown in Graph 11, box
represents screws.)
Disassembly of evaporator
Remark: Make sure that the power supply is cut off and protect the copper tube and aluminum fin. If
the time for disassembly shall be long, put the copper tube under pressurized condition.
Step
Illustration
Handling Instruction
1. Disassembly of
fixing screws on the
side panels of
evaporator
Disassemble the fastening
screw connecting left and
right side panels on the
evaporator and the upper
cover plate. (As is shown in
the arrows direction in
Graph.)
2. Disassemble
fastening screws
connecting evaporator
valve seal-plate and
joint flange
Disassemble the fastening
screws on the valve
seal-plate and remove the
valve seal-plate.
Disassemble the fastening
screws on the evaporators
joint flange. (As is shown in
the graph, box represents
fastening screws on
seal-plates while circle the
fastening screws on joining
flange.