DC Inverter Multi VRF System   
 
31 
 
 
(2) Following circumstances are not malfunctions. 
Unit  starts  up  immediately  after  it  is 
turned off. 
Overload  protection switch  makes  it  run  after a 
3-min delay. 
Standby operation lasts for about 1min. 
Mist  comes  from 
the unit. 
Indoor air with high humidity is cooled rapidly. 
Slight cracking sound is heard when unit 
is just turned on. 
It is the noise when electronic expansion valve is 
initialized. 
There  is  consecutive  sound  when 
cooling. 
It is  the  sound for  gas  refrigerant  flowing in the 
unit. 
There is sound when unit starts or stops. 
It  is  the  sound  when  gas  refrigerant  stops 
flowing. 
There  is  slight  and  consecutive  sound 
when unit is running or after running. 
This is the sound of drainage operation. 
Cracking  sound  is  heard  when  unit  is 
running or after running. 
This  is  the  sound  caused  by  the  expansion  of 
panel  and  other  parts  of  the  unit  due  to 
temperature change. 
Unit  starts  up  after  not  operating  for  a 
long time. 
Dust in indoor unit is blown out. 
Unit  absorbs  the  room  odor  and  then  blows  it 
out. 
7 Error Indication 
Inquiry method of error indication: combine division symbol and content symbol to check the 
corresponding error. 
For example, division symbol L and content symbol 4 together means over-current protection. 
Malfunction of IDU (uniform) 
Auxiliary heating protection 
Freeze prevention protection 
Power supply is insufficient 
1-to-more: number of IDU is 
inconsistent 
1-to-more: IDU series is 
inconsistent 
Alarm due to bad air quality 
(Fresh air unit) 
Models for IDU and ODU are 
not matched 
Drop protection of discharge 
temperature sensor of 
compressor 1 
Malfunction of ambient 
temperature sensor 
Malfunction of entry-tube 
temperature sensor 
Malfunction of middle temperature 
sensor 
Malfunction of exit-tube 
temperature sensor 
Malfunction of humidity sensor 
Malfunction of jumper cap 
Web address of IDU is abnormal 
PCB of wired controller is 
abnormal 
Abnormal setting for capacity 
button 
Malfunction of air-outlet 
temperature sensor(Fresh air 
unit) 
Malfunction of indoor CO
2
 sensor 
(fresh air unit) 
Gas-mixing protection of 4-way 
valve 
High pressure ratio protection 
of system 
Low pressure ratio protection of 
system 
Protection due to abnormal 
pressure 