GREE GMV5 INDOOR UNIT SERVICE MANUAL
56
status. After quiting the function setting status, the icon is on, it means the timer function has been
turned on.
Cancel timer: press Function button to switch to timer function, when icon flickers, press
“▲”or”▼” button to set the time to be 00, then the timer function is canceled; press ON/OFF button or
without pressing any buttons for consecutive 5 seconds, it will quit the function setting status. After quiting
the function setting status, the icon is off, it means the timer function has been canceled.
Count down setting range: 00~24 hours, in which 00 refers to closedown of timer function. Each
time press “▲” or “▼” button, if it is within 10 hours, it will increase or decrease 0.5 hour each time, if
long press “▲” or “▼” button, it will increase or decrease 0.5 hour every 0.3 second; if it is over 10 hours,
each time press “▲” or “▼” button will increase or decrease 1 hour each time, and if long press “▲” or
“▼” button, it will increase or decrease 1 hour every 0.3 second.
(5) Setting of air renewal function
Air renewal function: through adjusting the fresh air volume to improve the air quality and keep the
indoor fresh air.
Air renewal setting: press Function button to switch to air renewal function, when icon flickers,
press “▲”or”▼” button to adjust the air renewal level; after setting air renewal level, press ON/OFF
button or without pressing any buttons for consecutive 5 seconds, the air renewal function has been
confirmed to be turned on and then quit the function setting status. After quiting the function setting status,
the icon is on, it means the air renewal function has been turned on.
Cancel air renewal: press Function button to switch to air renewal function, when icon flickers,
press “▲”or”▼” button to set the air renewal as 00, then the air renewal function is canceled; press
ON/OFF button or without pressing any buttons for consecutive 5 seconds, it will quit the function setting
status. After quiting function setting status, the icon is off, it means the air renewal function is
canceled.
Adjustment range of air renewal level: it can adjust the air renewal level to be 00~10, in which 00
refers to closing down air renewal function.
(6) Setting of Sleeping Function
Sleeping function: set the unit to enter into sleeping operational status, the unit will operate according
to the preset sleeping temperature curve to create a confortable sleeping environment and improve
sleeping quality.
Turn on or cancel sleeping function: press Function button under power-on status to switch to
sleeping function, when icon flickers, press “▲”or”▼” button to turn on or cancel sleeping function.
If icon is on, it means the sleeping function is turned on; if icon is off, it means the sleeping
function is canceled.
There is no sleeping function under auto and swing mode.

Table of Contents

Other manuals for Gree GMV-N140U/A-T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GMV-N140U/A-T and is the answer not in the manual?

Gree GMV-N140U/A-T Specifications

General IconGeneral
BrandGree
ModelGMV-N140U/A-T
CategoryAir Conditioner
LanguageEnglish

Related product manuals