61
Maintenance
Service Manual
Step
Procedure
15.
16 .
17.
Remove water level switch sub-assy
Remove compressor and ttings
Remove motor sub-assy(utter)
Unscrew 4 screws to remove the water level
switch sub-assy.
Unscrew 3 bolts of compressor chassis,
then take out gasket to remove compressor.
Unscrew 2 screws of bottom of
sub-assy to remove motor sub-assy.
Screws
Water level switch sub-assy
Bolts
Screws
Motor sub-assy(utter)
Bolts
Compressor
and ttings