EasyManua.ls Logo

Gree GUD50ZD/A-T - Page 111

Gree GUD50ZD/A-T
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GREE U-Match 5 SERIES UNIT SERVICE MANUAL
106
Disassembly of compressor
Note: Before removing the compressor, make sure there is no refrigerant in the pipeline and power is cut off.
Step
Picture
Work instruction
5.Fix the new compressor back
onto the chassis.
After replacing the compressor,
tighten up the screws at the foot
of compressor.
6.Connect the compressor suction
port and exhause port with the
pipes.
Weld the compressor
connection pipes and connect
them to the compressor.
Note: When replacing the
compressor, avoid touching the
nearby pipeline and components.
8.Connect the compressor wires.
Connect the compressor wires
to the wire terminals on the top of
compressor.
Note: When connecting the
wires, be sure to match the colors
with the corresponding wire
terminals.

Table of Contents

Other manuals for Gree GUD50ZD/A-T

Related product manuals