Thank you for choosing Air Conditioners, please read this owner’s manual carefully before operation
and retain it for future reference.If you have lost the Owner’s Manual, please contact the local agent or
visit www.gree.com or send email to global@gree.com.cn or electronic version.
GREE reserves the right to interpret this manual which will be subject to any change due to product
improvement without further notice.
GREE Electric Appliances, Inc. of Zhuhai reserves the final right to interpret this manual.
Cassette Type
Air Conditioner Unit

Other manuals for Gree GUHN36NM3HO

Questions and Answers

  • J
    joshuameadowsAug 9, 2025
    Why is my Gree Air Conditioner not cooling properly?
    • R
      Rachel RiveraAug 9, 2025
      Several factors can cause a Gree Air Conditioner to have a poor cooling effect. The air filter might be dirty or blocked, so cleaning or replacing it is recommended. There might be too many people or heat sources in the room; try to reduce these. Ensure all doors and windows are closed. Obstacles at the air intake or outlet should be removed. The set temperature might be too high, so lower it. A refrigerant leakage could also be the cause, requiring a check and refill. Lastly, the room temperature sensor might be faulty, and testing or replacing it may be necessary.
  • J
    joseph65Aug 15, 2025
    Why does my Gree GUHN36NM3HO operate for a while and then stop?
    • J
      Jennifer RiveraAug 15, 2025
      If your Gree Air Conditioner operates for a while and then stops, check for any obstacles in front of the condenser and remove them. The control loop might be abnormal, requiring a check and repair. Also, if you're using cooling operation when the outdoor temperature is above 48°C, change the operation mode.
  • M
    Matthew HamiltonAug 21, 2025
    How to improve the heating effect of my Gree Air Conditioner?
    • M
      Matthew RodriguezAug 21, 2025
      To improve the heating effect of your Gree Air Conditioner, start by cleaning or replacing the air filter if it's dirty or blocked. Ensure that all doors and windows are firmly closed. If the set room temperature is too low, raise it. Check for refrigerant leakage and refill if necessary. If the outdoor temperature is below -5°C, consider supplemental heating or check if the operation is appropriate. Finally, check and repair the control loop if it is abnormal.
  • R
    Richard JordanAug 27, 2025
    What to do if my Gree GUHN36NM3HO unit cannot be started?
    • M
      Michelle LeeAug 27, 2025
      If your Gree Air Conditioner won't start, first check the power supply connection. If the leakage switch is tripping, inspect for electrical leakage and correct it. Also, make sure the operating keys are not locked and unlock them if they are. If none of these resolve the issue, test and repair the control loop.
  • K
    Kristin BryanSep 2, 2025
    What to do if my Gree GUHN36NM3HO displays error code E1?
    • D
      Darren MooreSep 2, 2025
      If your Gree Air Conditioner shows the E1 error code, switch off the unit immediately and seek assistance from a qualified technician for maintenance.

Summary

Safety Precautions

General Safety Warnings and Cautions

Covers important warnings and cautions for safe operation and installation of the air conditioner.

Unit Installation Procedures

Indoor Unit Installation Steps

Covers unit dimensions, main body mounting, suspension bolts, and leveling.

Outdoor Unit Installation Guidelines

Details placement, dimensions, and condensate drainage for outdoor units.

Connection Pipe Installation

Details flare processing, bending, connecting pipes, and heat insulation.

Vacuum and Gas Leakage Inspection

Procedure for evacuating the system and checking for refrigerant leaks.

Test Running and Operation

Troubleshooting and Maintenance

Gree GUHN36NM3HO Specifications

General IconGeneral
Cooling Capacity36000 BTU/h
Heating Capacity36000 BTU/h
HSPF9.0
Voltage (V)220-240
RefrigerantR410A
TypeSplit System
Power Supply220-240V, 50Hz