EasyManua.ls Logo

Gree GVA60AH-M3NNA5A - Page 37

Gree GVA60AH-M3NNA5A
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
+PUVCNNCVKQP/CPWCN

1.Align the center of the piping flare with the pyramidal face of relevant valve.
2.Screw in the flare nut by hand and then tighten the nut with spanner and torque wrenc h
refer to the following.
Indoor unit piping Taper nut
Piping
Spanner Torque wrench
NOTE: Firstly connect the connection pipe to indoor unit, then to outdoor unit; pay attention to the piping bending,and do not dam
age
the connection pipe; the joint nut couldn’t tighten too much, otherwise it may cause leakage.
Installation of connection pipe
Fig.12
Hex nut Tightening torque (N.m)
Ф50.12
55
Ф19
70
75

Related product manuals