The above data is subject to change without notice. Please refer to the nameplate of the unit.
Outdoor
Unit
Outdoor Unit Model GVC48ALXL-M3NTC7B/O
Outdoor Unit Product Code CG156W08700
Compressor Manufacturer ZHUHAI LANDA COMPRESSOR CO., LTD.
Compressor Model QXAS-H59sN345A
Compressor Oil Ze-GLES RB68EP/FVC68D
Compressor Type Rotary
Compressor LRA. A 72
Compressor RLA A 9
Compressor Power Input W 4900
Compressor Overload Protector UP18UA14R-55E
Throttling Method Capillary
Set Temperature Range ºC 16~30
Cooling Operation Ambient Temperature Range ºC 18~52
Heating Operation Ambient Temperature Range ºC /
Condenser Form Aluminum Fin-copper Tube
Condenser Pipe Diameter mm Φ7
Condenser Rows-n Gap mm 2-1.4
Condenser Coil Length (LXDXW) mm 794X38.1X1232
Fan Motor Speed rpm 900
Fan Motor Power Output W 68
Fan Motor RLA A 0.65
Fan Motor Capacitor μF 4
Outdoor Unit Air Flow Volume m
3
/h 6000
Fan Type Axial-ow
Fan Diameter mm Φ472
Defrosting Method /
Climate Type T3
Isolation I
Moisture Protection IPX4
Permissible Excessive Operating Pressure for
the Discharge Side
MPa 4.3
Permissible Excessive Operating Pressure for
the Suction Side
MPa 2.5
Sound Pressure Level dB (A) 60
Sound Power Level dB (A) 70
Dimension(WXHXD) mm 978X1260X412
Dimension of Carton Box (LXWXH) mm 1025X435X1285
Dimension of Package(LXWXH) mm 1033X443X1405
Net Weight kg 98
Gross Weight kg 108
Refrigerant R410A
Refrigerant Charge kg 3.6
Connection
Pipe
Connection Pipe Length m 5
Connection Pipe Gas Additional Charge g/m 15
Outer Diameter Liquid Pipe 3/8"
Outer Diameter Gas Pipe 5/8"
Max Distance Height m 30
Max Distance Length m 40
Note: The connection pipe applies metric diameter.