Installation and Maintenance
Service Manual
d. After the above measurement, you will get 4 numerical values, if any one of them is not within the range of 0.3V~0.7V, it means
the rectier bridge is damaged.
Notices: during the measurement, please make sure that the battery of universal meter is sufcient and the pole has touched the
end (there may be glue in the surface of mainboard for damp proong, which may cause invalid touch of the pole).
6.2 IPM module
Appearance and inner diagram (the following diagrams are only for reference. It depends on different models and manufacturers.)