27
Technical Information
Service Manual
6. Function and Control
is set. Do not put the remote contro ller near the object of high
temperature or low temperature in order to avoid detecting
inaccurate amb ient temperature. When I FEEL function is turned
on, the remote controller should be put within the area where
indoor unit can receive the signal sent by the remote controller.
CLOCK
button
Press this button to set clock time. " " icon on remote controller
will blink. Press "▲" or " " button within 5s to set clock time.
Each pressing of "▲" or " " button, clock time will increas e or
decrease 1 minute.If hold "▲" or " " button, 2s later, time will
change quickly. Release this button when reaching your required
time. Press "CLOCK" button to conrm the time. " " icon stops
blinking.
Note:
● Clock time adopts 24-hour mode.
The interval between two operations can't exceed 5s.
Otherwise, remote controller will quit setting status. Operation for
TIMER ON/TIMER OFF is the same.
SLEEP
button
Press this button, can select Sleep 1 ( 1), Sleep 2 ( 2),
Sleep 3 ( 3) and cancel the Sleep, circulate between these,
after electried, Sleep Cancel is defaulted.
Sleep 1 is Sleep mode 1, in Cool modes; sleep status after run
for one hour, the main unit setting temperature will increase 1 ,
two hours, setting temperature increased 2
, then the unit will
run at this setting temperature; In Heat mode: sleep status after
run for one hour, the setting temperature will decrease 1 , two
hours, setting temperature will decrease 2 , then the unit will run
at this setting temperature.
Sleep 2 is sleep mode 2, that is air conditioner will run
according to the presetting a group of sleep temperature curve.
● Sleep 3-the sleep curve setting under Sleep mode by DIY;
(1) Under Sleep 3 mode, press “Turbo” button for a long
time, remote controller enters into user individuation sleep
setting status, at this time, the time of remote controller will
display1hour”, the setting temperature88” will display the
corresponding temperature of last setting sleep curve and blink
(The rst entering will display according to the initial curve setting
value of original factory);
(2) Adjust “+” and “-” button, could change the corresponding
setting temperature, after adjusted, press “Turbo” button for
conrmation;
(3) At this time, 1hour will be automatically increased at the timer
position on the remote control, (that are "2hours" or "3hours" or
"8hours"), the place of setting temperature "88" will display the
corresponding temperature of last setting sleep
curve and blink;
(4) Repeat the above step (2)~(3) operation, until 8 hours
temperature setting nished, sleep,curve setting nished, at this
time, the remote controller will resume the original timer display;
temperature display will resume to original setting temperature.
● Sleep3- the sleep curve setting under Sleep mode by DIY could
be inquired:
The user could accord to sleep curve setting method to inquire
the presetting sleep curve, enter into user individuation sleep
setting status, but do not change the temperature, press "Turbo"
button directly for conrmation. Note: In the above presetting or
enquiry procedure, if continuously within 10s, there is no button
pressed, the sleep curve setting within 10s, there is no button
pressed, the sleep curve setting status will be automatically quit
and resume to display the original displaying. In the presetting
or enquiry procedure, press "ON/OFF" button, "Mode" button,
"Sleep" button, the sleep curve setting or enquiry status will quit
similarly.
WiFi
button
Press " WiFi " button to turn on WiFi function, "WiFi " icon will
be displayed on the remote controller; Hold " WiFi " button for 5s
to turn off WiFi function and " WiFi " icon will disappear.
Under off status, press "MODE" and " WiFi " buttons
simultaneously for 1s, WiFi module will restore factory settings.
● This function is only available for some models.
button
Press this button to achieve the on and off of health and
scavenging functions in operation station. Press this button
for the first time to start scavenging function; LCD displays
" ". Press the button for the second time to start health and
scavenging functions simultaneously; LCD displays " " and " ".
Press this button for the third time to quit health and scavenging
functions simultaneously. Press the button for the fourth time to
start health function; LCD display " ". Press this button again to
repeat the operation above.
● This function is applicable to partial of models .
LIGHT
button
Press this button to turn off display light on indoor unit. " " icon
on remote controller disappears. Press this button again to turn
on display light. " " icon is displayed.
Press and hold the LIGHT button for 5 seconds to activate or
cancel the auto light function. When the set temperature on the
remote controller blinks 3 times, it means the auto light function is
successfully turned on. When this function is active, the panel
lamp will light up for 20 seconds every time the indoor unit
receives a signal from the remote controller and then go off
automatically.
Auto light function is only available for some models.
TEMP
button
Press this button, you can see indoor set temperature, indoor
ambient temperature on indoor unit' s display. The setting on
remote controller is selected circularly as below:
no display