78
Installation and Maintenance
Service Manual
Appendix:
Appendix 1: Reference Sheet of Celsius and Fahrenheit
Set temperature
Conversion formula for Fahrenheit degree and Celsius degree: Tf=Tcx1.8+32
Ambient temperature
 Fahrenheit 
display 
temperature
(℉)
Fahrenheit
(℉)
Celsius
(℃)
 Fahrenheit 
display 
temperature
(℉)
Fahrenheit
(℉)
Celsius
(℃)
 Fahrenheit 
display 
temperature
(℉)
Fahrenheit
(℉)
Celsius
(℃)
32/33 32 0 55/56 55.4 13 79/80 78.8 26
34/35 33.8 1 57/58 57.2 14 81 80.6 27
36 35.6 2 59/60 59 15 82/83 82.4 28
37/38 37.4 3 61/62 60.8 16 84/85 84.2 29
39/40 39.2 4 63 62.6 17 86/87 86 30
41/42 41 5 64/65 64.4 18 88/89 87.8 31
43/44 42.8 6 66/67 66.2 19 90 89.6 32
45 44.6 7 68/69 68 20 91/92 91.4 33
46/47 46.4 8 70/71 69.8 21 93/94 93.2 34
48/49 48.2 9 72 71.6 22 95/96 95 35
50/51 50 10 73/74 73.4 23 97/98 96.8 36
52/53 51.8 11 75/76 75.2 24 99 98.6 37
54 53.6 12 77/78 77 25
 Fahrenheit 
display 
temperature
(℉)
Fahrenheit
(℉)
Celsius
(℃)
 Fahrenheit 
display 
temperature
(℉)
Fahrenheit
(℉)
Celsius
(℃)
 Fahrenheit 
display 
temperature
(℉)
Fahrenheit
(℉)
Celsius
(℃)
61 60.8 16 69/70 69.8 21 78/79 78.8 26
62/63 62.6 17 71/72 71.6 22 80/81 80.6 27
64/65 64.4 18 73/74 73.4 23 82/83 82.4 28
66/67 66.2 19 75/76 75.2 24 84/85 84.2 29
68 68 20 77 77 25 86 86 30
1.Standard length of connection pipe(More details please refer to the specications)
2.Min length  of  connection  pipeFor  the  unit  with standard  connection pipe  of 5m,  there  is  no  limitation  for  themin length  of 
connection pipe. For the unit with standard connection pipe of 7.5m and 8m, the min length of connection pipe is 3m.
3.Max length of connection pipe(More details please refer to the specications
)
4.The additional refrigerant oil and refrigerant charging required after prolonging connection pipe
● After the length of connection pipe is prolonged for 10m at the basis of standard length, you should add 5ml of refrigerant oil for 
each additional 5m of connection pipe.
● The calculation method of additional refrigerant charging amount (on the basis of liquid pipe):
● Basing on the  length  of standard pipe,  add  refrigerant  according to the  requirement  as shown in the  table.   The  additional 
refrigerant charging amount per meter is different according to the diameter of liquid pipe. See Sheet 2.
● Additional refrigerant charging amount = prolonged length of liquid pipe X additional refrigerant charging amount per meter 
Appendix 2: Conguration of Connection Pipe
Additional refrigerant charging amount for R32
Diameter of connection pipe Indoor unit throttle Outdoor unit throttle
Liquid pipe Gas pipe
Cooling only,cooling 
and heating(g / m)
Cooling only(g / m) Cooling and heating(g / m)
Ф6 Ф9.5 or Ф12 16 12 16
Ф6 or Ф9.5 Ф16 or Ф19 40 12 40
Ф12 Ф19 or Ф22.2 80 48 96
Ф16 Ф25.4 or Ф31.8 136 24 96
Ф19 / 200 200 200
Ф22.2 / 280 280 280
Note: The additional refrigerant charging amount in Sheet 2 is recommendedvalue, not compulsory.